Vanguard Heating VP2000BTC Gas Heater User Manual


 
26
103876
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-5190.
SPECIFICATIONS
SERVICE
HINTS
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.
VP2000BTC VP2800BTC
Btu (Variable) 10,000/20,000 15,000/30,000
Type Gas Propane Only Propane Only
Ignition Piezo Piezo
Pressure Regulator Setting 8" W.C. 8" W.C.
Inlet Gas Pressure (in. of water)
Maximum 14" 14"
Minimum 11" 11"
Dimensions, Inches (H x W x D)
Heater
(Includes knobs & grill)
23.5 x 18.5 x 8.0 23.5 x 25.9 x 8.0
Carton 26 x 20.5 x 9.63 26 x 27.75 x 9.63
Weight (pounds)
Heater 22 30
Shipping 27 35