Vanguard Heating VMH26NR Indoor Fireplace User Manual


 
12
104325
COMPACT CLASSIC HEARTH FIREPLACE
VMH26NR
®
Red
Red
Fan Switch
(Auto/Off/On)
Blue
Blue
Thermostat
Switch
(N.O.)
Green
White
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
3
Auto
Red
Red
Fan Switch
(Auto/Off/On)
Blue
Blue
Thermostat
Switch
(N.O.)
Green
White
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
3
Auto
Figure 19 - Installing Blower Bracket Assembly
Valve
Cover
Shield
Switch Plate
Screw
9. Install the switch plate on the valve
cover shield with 2 #10 screws provided
(see Figure 17). Route power cord out
of the cabinet by inserting it through
the bushing on the outer casing (see
Figure 16, page 11). Plug fan kit into
120-Volt grounded power supply and
test operation.
Note:
When switch is
in the AUTO position, the fan will start
after the heater has run for a few mo-
ments. The fan will continue to run for
several moments after the heater has
been turned off. When switch is in the
ON position, the fan will run until
turned to OFF. Reinstall upper louver
assembly (see Figure 15, page 11) and
twig support. Close lower louver door.
Figure 17 - Installing Switch Plate to Valve
Cover Shield
INSTALLATION
Continued
For Built-In Installation
WARNING: A licensed electri-
cian must connect the wiring har-
ness to electrical supply follow-
ing all local codes. Electrician
must provide a clamp on the box
cover to secure the wiring. Wir-
ing should be routed through the
bushing in the hole on the outer
casing of heater.
1. Install a snap bushing found in hard-
ware kit into one of the holes found rear
of valve cover shield. The other hole is
for a strain relief clamp (not supplied)
to secure incoming electrical supply.
2. Follow steps 2 through 6 in Installing
Blower Assembly, page 11.
3. A licensed electrician must follow the
wiring diagram to connect incoming
electrical supply to fan kit wiring harness
(see Figure 20).
Figure 18 - Wiring Diagram For Blower
Accessory Standard Installation
Blower Bracket
Assembly
Screw
Wire
Harness
Power
Cord
Plastic
Wire
Strap
Wire
Harness
Switch
Plate
Switch
Clamp Connector
(not included)
Blue
Red
Outlet
Receptacle
(Not Supplied)
Figure 20 - Wiring Diagram For Blower
Accessory Built-In Installation
4. Plug power cord to the outlet receptacle
(not provided) as shown in figure 19.
Wind the extra cable in power cord and
and tie it up with the plastic wire strap
(see Figure 19). Set the cable bundle
between the burner bracket and outer
casing, away from the burner.
5. Test to make sure the blower is work-
ing properly.
6. Reinstall upper louver assembly (see Fig-
ure 15, page 11) and close lower louver.