Vanguard Heating VGN30 Gas Heater User Manual


 
5
INSTALLING
TO WALL
NOTICE
A qualified service person must install heater. Follow all local codes.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, do not install heater. Call
dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing the heater, make sure you have the items listed below.
piping (check local codes)
sealant (resistant to propane gas)
manual shutoff valve *
ground joint union
test gauge connection * (see
Figure 10, page 11)
sediment trap
tee joint
pipe wrench
* An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design certified
manual shutoff valve from your dealer. See ACCESSORIES, page 23.
LOCATING HEATER
This heater is designed to be mounted on a wall.
!
WARNING ICON G 001
WARNING
Maintain the minimum clearances shown in Figure 2 (page 6). If
you can, provide greater clearances from floor, ceiling, and join-
ing wall.
Continued
!
WARNING ICON G 001
WARNING
Never install the heater
in sleeping quarters, a mobile home, or a recreational vehicle
where curtains, furniture, clothing, or other flammable objects
are less than 36 inches from the front, top, or sides of the
heater
as a fireplace insert
in high traffic areas
in windy or drafty areas
NOTICE
Do not install or operate heater in areas where impurities in the air
(such as tobacco smoke) exist. Particles from these impurities may
discolor walls.