Vanguard Heating VGN30 Gas Heater User Manual


 
21
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA Internationals Technical Service Department at 1-800-323-
5190.
SPECIFICATIONS
When gas pressure is too low
pilot will not stay lit
burner will have delayed ignition
heater will not produce specified heat
When gas quality is bad
pilot will not stay lit
burner will produce flames and soot
heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
SERVICE
HINTS
B.T.U (Variable) 15,000/30,000
Type Gas Natural Only
Ignition Piezo
Pressure Regulator Setting 3" W.C.
Inlet Gas Pressure (inches of water)
Maximum 7"
Minimum 5"
Dimensions, Inches (H x W x D)
Heater 23.5 x 25.9 x 8.0
Carton 25.8 x 28.7 x 10.1
Weight (pounds)
Heater 30
Shipping 35