PRODUCT SPECIFICATION
VE32 = 15
5
/
8
"
VE36 = 17"
VE32 = 16
1
/
4
"
VE36 = 17
5
/
8
"
VE32 = 22
1
/
4
"
VE36 = 24
1
/
4
"
VE32 = 29
3
/
8
"
VE36 = 35"
VE32 = 7"
VE36 = 8"
VE32 = 6
1
/
2
"
VE36 = 5
1
/
4
"
VE32 = 18
3
/
8
"
VE36 = 21"
VE32 = 33
3
/
8
"
VE36 = 37"
VE32 = 36
3
/
8
"
VE36 = 43"
VE32 = 35
3
/
8
"
VE36 = 42"
VE32 = 34
5
/
8
"
VE36 = 41
1
/
4
"
VE32 = 32
5
/
8
"
VE36 = 36
1
/
4
"
VE32 = 28
3
/
8
"
VE36 = 31
3
/
4
"
VE32 = 32
7
/
8
"
VE36 = 36
1
/
2
"
1
7
/
8
"
5/8"
TOP
FRONT
LEFT SIDE RIGHT SIDE
VE32 = 32
1
/
8
"
VE36 = 36
1
/
8
"
VE32 = 28
3
/
8
"
VE36 = 31
3
/
4
"
To Nail
Location
To Nail
Location
VE32 = 8"
VE36 = 5
1
/
4
"
ELECTRICAL SPECIFICATIONS
Voltage: 120 VAC, 60 Hz
Total Amps: 12.5 Amps
Total Watts: 1500 Watts
Heater Rating: 1100 Watts
Max. Bulb Rating: 100 Watts
Use only on 15 amp circuit
Figure 1 - Unit Dimensions
INSTALLATION
LOCATING FIREPLACE
Plan where to locate and frame replace.
Before installation consider the following:
1. Fireplace location must allow for wall and
ceiling clearances (see Installation Clear-
ances, page 4).
2. Fireplace screen should not be exposed
to direct sunlight from windows or doors.
3. A 15 amp, 120 Volt, 60 Hz circuit with
proper ground must be available. A dedi-
cated circuit should be provided to avoid
circuit breaker trips or blown fuses.
Prefab Mantel Installations are not perma-
nent and are low cost and easy to install on an
open wall space or a corner with an accessible
electrical outlet.
Flush Installations are recommended where
living space is limited or at a premium. Since
the space required to enclose the replace
would be located beyond an outside wall, this
installation would require additional planning
and construction. Check local codes for any
restrictions.
Projected Installations can extend any
distance into the room. A projection may
be ideal for a new addition on an existing,
nished wall.
Corner Installations make use of space
that may not normally be used and provides
a wider and more efcient viewing angle and
heat distribution.
Internal Wall Installations provide a discrete
option for room separation and can also be an
ideal addition to an existing wall.
Figure 2 - Possible Installation Locations
Internal Wall
Installation
Full Projection
Installation
Flush
Installation
Corner