Annual inspection and cleaning by your dealer or qualified service technician is recommended to
prevent malfunction and/or sooting.
Remove front screen, (see page 11). Carefully lift screen from locating stubs and set aside during
cleaning. Refer to instructions on page 11 for installation of screen. Do not operate the unit with the
screen removed.
Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent
skin irritation from ceramic. If the skin becomes irritated, wash gently with soap and water. Refer to
manual for correct log placement.
PILOT FLAME
The pilot flame should always be present when
the heater is in operation and should just touch
the top of the thermocouple tip (FIGURE 10).
FIGURE 10. Pilot Flame
If the pilot flame does not touch the thermo-
couple, then the main burner is unlikely to func-
tion reliably (FIGURE 11).
FIGURE 11. Incorrect Shape of Pilot Flame
Wait 30 seconds before readjusting the heater when the control has been
turned down to a lower setting.
WARNING
MATCH LIGHTING INSTRUCTIONS
If the pilot will not light using the piezo ignitor, you can light the pilot with a match. First, locate the pilot.
The pilot is located between the two burner tubes on the right end (facing the unit), inside the firebox.
To light pilot with a match, move the gas control (knob B, pg. 12) to the pilot position and hold down.
Light match and place near pilot. Once pilot is lit, continue to hold the knob for about ten seconds.
Then follow steps 7 thru 10 on page 12.
CHECKING FLAME APPEARANCE
Flames from the pilot, and burner should be visually checked when the heater is installed. In addition
a periodic visual check of the flames should be made.
OPERATING INSTRUCTIONS
CLEANING / SERVICING
WARNING
Turn off heater and allow to cool before cleaning.
14