United States Stove 2000 Stove User Manual


 
Ussc 7
CLEARANCES TO COMBUSTIBLES
Itisofutmostimportancethattheclearancestocombustiblematerialsbestrictlyadheredtoduring
installationofthestove.Refertothetablesbelow:
• Floortoceilingheightmustbeatleast7’(84”)inallcases.
• Donotplaceanycombustiblematerialwithin48”ofthefrontoftheunit.
• Theclearancebetweentheuepipeandawallarevalidonlyforverticlewallsandforverticleue
pipe.
• Theuepipemustnotgothroughrooftrussing,anattic,acloset,aoor,acombustiblepartition,
orsimilarspaces.
• Auepipecrossingacombustiblewallmusthaveaminimumclearanceof18”.
• Toreduceueclearancesfromcombustiblematerials,contactyourlocalsafetydepartment.
Single Wall Pipe (Double Wall Pipe)
Model A B C D E F
2000 20(14) 22(20) 22.5(16.5) 32(30) 12(11) 22(21)
2500 12 20 16 30 10.5 20