Trek SSDVST-CNE Indoor Fireplace User Manual


 
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
25
Figure 43 - Millivolt Wiring Diagram
Field Wired
Factory
Wired
TH
TP
TH
TP
* Optional
Control Switch
Thermopile
Schematic
Representation
Only
• If any of the original wire as supplied must
be replaced, it must be replaced with Type AWM
105 C - 18 gage wire.
* Optional Kits Installed - ON/OFF wall switch, unit mounted burner ON/OFF switch, wall thermostat or
remote control.receiver.
PT
*
* Twist wires together to operate unit
solely by manipulating the gas valve
control knob; or connect wires to
optional control switch (wall switch,
remote control or wall thermostat to
operate unit.
Step 4. FIELD WIRING
Refer to Section A for millivolt appliances and
Section B for electronic appliances.
A. Millivolt Wiring (See Figure 43):
1. Install and wire in the burner control switch.
Install either "a" or "b" below, NOT BOTH
(installing both may result in improper burner
operation).
a. Optional OFF/ON Switch - Install the
OFF/ON burner control switch (rocker
switch) as shown in Figures 43 &
44.
b. Optional Wall Switch, Wall Thermostat
Or Remote Control Receiver - Install
snap bushing (provided in Electrical
Outlet Kit) into control switch knock-
out in side panel (see Figures 13,14 &
45). Wire the optional control switch
within the millivolt control circuit (as
shown in Figure 43) using the 15 feet
of 2 conductor wire supplied (route
wires through the snap bushing to
the optional control switch). Mount
the optional control switch or wall
thermostat in a convenient location
on a wall near the fi replace.
CAUTION: DO NOT CONNECT OPTIONAL
CONTROL SWITCH TO 120VAC POWER
SUPPLY.
2. Install the junction box and receptacle outlet
to the left of the valve in the front (for optional
blower kit). See junction box and receptacle
outlet as explained in steps 1-11 for (B)
Electronic Wiring (on this page).
CAUTION
Label all wires prior to disconnec-
tion when servicing controls. Wiring
errors can cause improper and dan-
gerous appliance operation.
Gas
Valve
Control Compartment
Access panel
OFF/ON
Switch
TP TH
TH
Install OFF/ON Switch
(millivolt models)
1. Connect the 2 wires (provided in Electrical
Outlet Kit) to the TP/TH and TH terminals
on valve.
2. Pass the 2 wires through the opening where
OFF/ON switch will be installed (left of piezo,
below valve).
3. Connect the two wires to the OFF/ON
Switch.
OFF/ON
Switch
Connect
wires to
terminals
4. Press the OFF/ON switch into bracket as
shown below (it will snap into place).
Figure 44
B. Electronic Wiring (See Figures 45 & 46)
Notes:
The electronic appliance must be connected
to the main 120 VAC power supply.
The junction box can be installed in any of the
4 outside corners of the control compartment (it
can be found factory installed in the right front
corner viewed from the valve access side (where
it should be reinstalled if an optional blower kit
is installed).
1. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power
supply to the location on appliance where
junction box is to be installed.
2. Open the control compartment access panel
(see Control Compartment Access Instruc-
tions on Page 27).
3. Remove the junction box/outlet receptacle
assembly by removing the securing screw at
the front right corner of the unit. See Figure
45.
4. Remove the outlet receptacle from the
junction box by removing the two securing
screws.
5. Install a fi eld-provided strain relief in the
cabinet knockout opening for the protection
of the power supply wires.
6. Connect the power supply wires to the
receptacle as shown in Figure 46 on Page
26.
7. Connect the ground supply wire to the green
wire attached to the outlet receptacle’s
green ground screw.
8. Wire and install the outlet receptacle to
junction box. Next, install into the chosen
corner of the control compartment as shown
in Figure 45.
9. After the receptacle/junction box wiring is
complete, install the fi eld-provided metal
junction box cover plate (see Figure 45).
Note: The supplied 15 feet of 2 conductor
wire has one end of each conductor con-
nected to the gas valve circuit and the other
end of each conductor placed loose on top
of the appliance.
IMPORTANT NOTE
The gas valve OFF/ON switch is
shown in Figure 46 on Page 26. It
is integral with the gas valve and
should be set to the ON position.