Performance
Data
Table PD-25 Auxiliary Electric Heat Capacity Air Handler
No. Stage 1 Stage 2 Total
Unit Total of KW Btuh KW KW Btuh KW Btuh KW
Model No. KW Stages Input Output Output Input Output Output Output Output
TWE050, 075,100 3.47 1 3.47 11,851 3.47 11,851 3.47
6.92 1 9.92 23,606 6.92 23,606 6.92
10.39 1 10.39 35,457 10.39 35,457 10.39
17.31 2 10.39 35,457 10.39 6.92 23,606 6.92 59,063 17.31
TWE075, 100A, 100 24.22 2 13.83 47,213 13.83 10.39 35,457 10.39 82,670 24.22
TWE155, 200 6.94 1 6.94 23,701 6.94 23,701 6.94
13.83 1 13.83 47,213 13.83 47,213 13.83
20.78 2 13.83 47,213 13.83 6.94 23,701 6.94 70,915 20.78
34,62 2 20.78 70,915 20.78 13.84 47,213 13.89 118,128 34.61
*Heaters are rated at 400v. For other than rated voltage,
Capacity =
Voltage
2
x Rated Capacity and KW =
Voltage
2
x Rated KW.
(
Rated Voltage
)(
Rated Voltage
)