Pub. No. 22-1847-03 11
Minimum Heating Airow Settings
TAM7A0C48 AIRFLOW PERFORMANCE
CONSTANT CFM MODE / CONSTANT TORQUE MODE
OUTDOOR
MULTIPLIER
(TONS)
COOLING
AIRFLOW
SETTING
Airow
Power
EXTERNAL STATIC PRESSURE
HEATING
AIRFLOW
SETTING
Airow
Power
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
3 tons
330
CFM/ton
CFM
Watts
1101 / 1127
92 / 117
1017 / 1020
143 / 143
1015 / 907
190 / 163
1006 / 786
232 / 173
994 / 654
270 / 174
380
CFM/ton
CFM
Watts
1150
128
1155
184
1154
237
1150
286
1141
330
350
CFM/ton
CFM
Watts
1067 / 1180
106 / 132
1073 / 1078
158 / 160
1072 / 972
208 / 180
1065 / 859
252 / 192
1053 / 738
292 / 194
400
CFM/ton
CFM
Watts
1204
145
1210
203
1210
259
1207
310
1199
356
370
CFM/ton
CFM
Watts
1122 / 1233
120 / 149
1129 / 1136
175 / 177
1128 / 1035
227 / 199
1122 / 929
274 / 212
1112 / 816
315 / 215
420
CFM/ton
CFM
Watts
1259
162
1266
224
1267
282
1264
335
1258
384
390
CFM/ton
CFM
Watts
1177 / 1287
136 / 167
1185 / 1194
194 / 196
1185 / 1097
248 / 219
1180 / 996
297 / 233
1170 / 890
341 / 238
440
CFM/ton
CFM
Watts
1314
182
1322
246
1324
307
1322
363
1316
413
3.5 tons
330
CFM/ton
CFM
Watts
1164 / 1274
132 / 162
1171 / 1179
189 / 191
1171 / 1082
242 / 214
1165 / 980
291 / 227
1156 / 872
334 / 232
380
CFM/ton
CFM
Watts
1323
185
1331
250
1333
250
1331
368
1325
418
350
CFM/ton
CFM
Watts
1228 / 1336
152 / 185
1235 / 1246
212 / 215
1236 / 1153
268 / 238
1232 / 1056
319 / 253
1224 / 955
365 / 259
400
CFM/ton
CFM
Watts
1388
211
1398
279
1400
343
1399
403
1395
457
370
CFM/ton
CFM
Watts
1292 / 1400
174 / 210
1300 / 1313
237 / 241
1302 / 1224
296 / 265
1299 / 1132
350 / 281
1292 / 1036
399 / 288
420
CFM/ton
CFM
Watts
1455
240
1465
312
1468
379
1469
441
1463
497
390
CFM/ton
CFM
Watts
1356 / 1465
198 / 238
1366 / 1381
265 / 270
1369 / 1295
327 / 295
1367 / 1207
384 / 312
1361 / 1115
435 / 320
440
CFM/ton
CFM
Watts
1523
272
1534
347
1538
418
1538
483
1534
542
4 tons †
330
CFM/ton
CFM
Watts
1315 / 1443
212 / 228
1324 / 1358
247 / 260
1326 / 1271
307 / 284
1323 / 1181
362 / 301
1316 / 1088
412 / 308
380
CFM/ton
CFM
Watts
1502
262
1514
337
1518
406
1518
471
1514
529
350 †
CFM/ton
CFM
Watts
1389 / 1517
212 / 262
1399 / 1436
280 / 295
1403 / 1352
343 / 321
1401 / 1266
402 / 338
1395 / 1177
455 / 346
400
CFM/ton
CFM
Watts
1582
302
1594
382
1598
454
1598
522
1591
581
370
CFM/ton
CFM
Watts
1465 / 1594
245 / 301
1476 / 1516
317 / 335
1481 / 1435
384 / 361
1480 / 1352
446 / 379
1475 / 1267
502 / 388
420
CFM/ton
CFM
Watts
1664
348
1675
421
1680
508
1678
577
1669
638
390
CFM/ton
CFM
Watts
1543 / 1673
283 / 346
1555 / 1597
359 / 380
1560 / 1519
430 / 406
1560 / 1439
495 / 425
1554 / 1356
553 / 434
440
CFM/ton
CFM
Watts
1748
400
1758
486
1760
565
1755
634
1708
668
4.5 tons **
330
CFM/ton
CFM
Watts
1470 / 1599
247 / 304
1481 / 1521
319 / 337
1486 / 1440
387 / 364
1485 / 1357
449 / 382
1480 / 1272
505 / 391
380
CFM/ton
CFM
Watts
1695
367
1706
451
1710
528
1707
598
1697
659
350
CFM/ton
CFM
Watts
1558 / 1688
290 / 354
1570 / 1613
367 / 389
1575 / 1535
439 / 415
1575 / 1455
505 / 434
1568 / 1373
563 / 444
400
CFM/ton
CFM
Watts
1790
428
1799
515
1799
594
1792
664
1700
661
370
CFM/ton
CFM
Watts
1649 / 1780
340 / 412
1661 / 1707
422 / 447
1666 / 1632
497 / 474
1664 / 1554
565 / 493
1655 / 1475
625 / 503
420
CFM/ton
CFM
Watts
1885
496
1889
584
1884
662
1783
656
1683
648
390
CFM/ton
CFM
Watts
1742 / 1873
397 / 477
1754 / 1801
483 / 512
1756 / 1728
561 / 539
1751 / 1653
630 / 558
1708 / 1576
666 / 567
440
CFM/ton
CFM
Watts
1976
568
1973
655
1871
652
1765
643
1667
636
NOTES:
1. † Factory Setting
2. Status LED will blink once per 100 CFM requested. In torque mode, actual airow may be lower.
3. Torque mode will reduce airow when static is above approximately 0.4"
water column.
4. All heating modes default to Constant CFM
5. Cooling airow values are with wet coil, no lter
6. ** Not an actual OD size.
NOTE: Minimum auxiliary heating airow is automatically congured by the air handler model and
the auxiliary heater model number. This is not eld adjustable.
MODEL NO.
BAYEVAC05BK1A
A
BAYEVAC05LG1AA
BAYEVAC08BK1A
A
BAYEVAC08LG1AA
BAYEVAC10BK1A
A
BAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVCB15LG3AA BAYEVBC15BK1AA BAYEVBC20BK1AA BAYEVCC25BK1AA
TAM7A0C48H41SB 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625/1813
MINIMUM HEATER AIRFLOW CFM - HEATER MATRI
X
WITHOUT HEAT PUMP / WITH HP
SEE AIR HANDLER NAMEPLATE FOR APPROVED COMBINATIONS