Trane TAM7A0C42H31SB Air Conditioner User Manual


 
12 Pub. No. 22-1847-03
Minimum Heating Airow Settings
TAM7A0C60H51SB, TAM7B0C60H51SA AIRFLOW PERFORMANCE
CONSTANT CFM MODE / CONSTANT TORQUE MODE
OUTDOOR
MULTIPLIER
(TONS)
COOLING
AIRFLOW
SETTING
Airow
Power
EXTERNAL STATIC PRESSURE
HEATING
AIRFLOW
SETTING
Airow
Power
EXTERNAL STATIC PRESSURE
0.1 0.3 0.5 0.7 0.9 0.1 0.3 0.5 0.7 0.9
3.5 tons
370
CFM/ton
CFM
Watts
1316 / 1404
194 / 201
1328 / 1330
258 / 234
1328 / 1244
314 / 260
1320 / 1146
364 / 276
1308 / 1033
406 / 280
400
CFM/ton
CFM
Watts
1404
205
1424
275
1426
337
1419
391
1410
440
380
CFM/ton
CFM
Watts
1349 / 1435
207 / 213
1360 / 1362
272 / 247
1359 / 1278
329 / 273
1352 / 1183
380 / 290
1338 / 1074
422 / 295
410
CFM/ton
CFM
Watts
1437
218
1455
289
1457
351
1451
407
1441
456
390
CFM/ton
CFM
Watts
1381 / 1466
220 / 225
1391 / 1394
286 / 260
1390 / 1312
344 / 287
1383 / 1220
396 / 304
1370 / 1115
439 / 310
420
CFM/ton
CFM
Watts
1467
230
1487
303
1489
367
1482
423
1474
474
400
CFM/ton
CFM
Watts
1413 / 1496
234 / 238
1422 / 1426
300 / 273
1421 / 1346
360 / 301
1415 / 1256
412 / 319
1402 / 1154
456 / 325
430
CFM/ton
CFM
Watts
1500
244
1516
317
1519
382
1515
441
1505
491
4 tons
370
CFM/ton
CFM
Watts
1485 / 1583
269 / 278
1493 / 1516
337 / 314
1493 / 1441
398 / 342
1486 / 1357
452 / 362
1475 / 1263
498 / 370
400
CFM/ton
CFM
Watts
1586
285
1600
360
1604
428
1601
490
1592
543
380
CFM/ton
CFM
Watts
1521 / 1618
287 / 295
1529 / 1552
356 / 331
1528 / 1479
418 / 360
1522 / 1396
474 / 380
1511 / 1305
520 / 389
410
CFM/ton
CFM
Watts
1622
303
1636
379
1640
449
1638
512
1629
566
390
CFM/ton
CFM
Watts
1557 / 1654
306 / 313
1564 / 1589
376 / 350
1564 / 1516
440 / 379
1559 / 1436
496 / 400
1548 / 1347
544 / 409
420
CFM/ton
CFM
Watts
1659
322
1672
399
1677
471
1675
535
1667
591
400
CFM/ton
CFM
Watts
1593 / 1689
326 / 332
1600 / 1625
397 / 369
1600 / 1554
462 / 399
1595 / 1475
519 / 420
1585 / 1389
568 / 430
430
CFM/ton
CFM
Watts
1695
342
1708
421
1713
493
1712
559
1705
616
4.5 tons**†
370 †
CFM/ton
CFM
Watts
1652 / 1748
360 / 365
1659 / 1685
433 / 403
1660 / 1616
500 / 433
1655 / 1540
559 / 454
1646 / 1456
610 / 465
400
CFM/ton
CFM
Watts
1769
385
1782
467
1789
543
1788
611
1783
671
380
CFM/ton
CFM
Watts
1694 / 1789
386 / 390
1701 / 1727
460 / 427
1701 / 1659
528 / 458
1697 / 1548
589 / 480
1688 / 1503
641 / 491
410
CFM/ton
CFM
Watts
1811
411
1826
495
1831
572
1832
643
1827
704
390
CFM/ton
CFM
Watts
1736 / 1831
413 / 416
1742 / 1770
489 / 454
1744 / 1703
558 / 484
1740 / 1629
620 / 506
1732 / 1549
673 / 518
420
CFM/ton
CFM
Watts
1854
439
1869
525
1875
604
1877
676
1872
739
400
CFM/ton
CFM
Watts
1778 / 1873
442 / 443
1785 / 1813
519 / 481
1786 / 1747
590 / 512
1783 / 1675
653 / 534
1776 / 1597
707 / 546
430
CFM/ton
CFM
Watts
1898
468
1913
556
1919
637
1921
711
1918
777
5 tons
370
CFM/ton
CFM
Watts
1826 / 1921
475 / 476
1833 / 1862
555 / 515
1835 / 1797
627 / 545
1832 / 1726
692 / 568
1826 / 1650
748 / 580
400
CFM/ton
CFM
Watts
1963
515
1978
606
1985
689
1988
766
1985
833
380
CFM/ton
CFM
Watts
1875 / 1971
512 / 512
1882 / 1912
593 / 550
1884 / 1848
667 / 581
1882 / 1778
733 / 603
1876 / 1703
791 / 616
410
CFM/ton
CFM
Watts
2014
554
2029
647
2037
733
2040
811
2038
880
390
CFM/ton
CFM
Watts
1924 / 2021
551 / 550
1932 / 1963
634 / 588
1935 / 1900
710 / 619
1933 / 1832
777 / 641
1927 / 1758
836 / 654
420
CFM/ton
CFM
Watts
2066
595
2082
691
2090
779
2093
859
2090
928
400
CFM/ton
CFM
Watts
1975 / 2073
593 / 590
1983 / 2015
678 / 629
1986 / 1953
755 / 660
1985 / 1886
824 / 682
1979 / 1814
884 / 695
430
CFM/ton
CFM
Watts
2120
640
2136
738
2143
828
2147
909
2143
980
NOTES:
1. † Factory Setting
2. Status LED will blink once per 100 CFM requested. In torque mode, actual airow may be lower.
3. Torque mode will reduce airow when static is above approximately 0.4"
water column.
4. All heating modes default to Constant CFM
5. Cooling airow values are with wet coil, no lter
6. ** Not an actual OD size.
NOTE: Minimum auxiliary heating airow is automatically congured by the air handler model and
the auxiliary heater model number. This is not eld adjustable.
MODEL NO.
BAYEVAC05BK1A
A
BAYEVAC05LG1AA
BAYEVAC08BK1A
A
BAYEVAC08LG1AA
BAYEVAC10BK1AA
BAYEVAC10LG1AA BAYEVAC10LG3AA BAYEVCB15LG3AA BAYEVBC15BK1AA BAYEVBC20BK1AA BAYEVCC25BK1AA
TAM7B0C60H51S
A
TAM7A0C60H51SB 1063/1188 1063/1500 1125/1500 1000/1188 1125/1563 1250/1625 1500/1750 1625 1 /1813
WITHOUT HEAT PUMP / WITH HP
SEE AIR HANDLER NAMEPLATE FOR APPROVED COMBINATIONS
1
Heater not qualified for 208V when installed in horizontal left position without Heat Pump
MINIMUM HEATER AIRFLOW CFM - HEATER MATRIX