Trane 4TTB4 Fan User Manual


 
4 22-1833-09
ProductSpecications
Model No. 1 4TTB4018E1 4TTB4024E1 4TTB4030E1 4TTB4036E1
Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60
Min Cir Ampacity 9 9 12 19
Max Fuse Size (Amps) 15 15 20 30
Compressors CLIMATUFF
®
CLIMATUFF
®
CLIMATUFF
®
CLIMATUFF
® -
SCROLL
No. Used - No. Stages 1-1 1-1 1-1 1-1
RL AMPS - LR AMPS 6.4 - 38.6 6.8 - 38.6 9.1 - 57.8 14.1 - 77
Outdoor Fan FL Amps 0.74 0.74 0.93 0.93
Fan HP 1/8 1/8 1/5 1/5
Fan Dia (inches) 23 23 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™
Refrigerant R-410A 5/2-LB/OZ 6/3-LB/OZ 7/0-LB/OZ 7/4-LB/OZ
Line Size - (in.) O.D. Gas 3 5/8 3/4 3/4 3/4
Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8
Dimensions H x W x D (Crated) 34 x 30.1 x 33 34 x 30.1 x 33 38.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7
Weight - Shipping 200 201 234 228
Weight - Net 173 174 201 193
Start Components YES YES YES NO
Sound Enclosure YES YES YES NO
Compressor Sump Heat NO NO NO NO
Optional Accessories: 4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A
Evaporator Defrost Control A/C AY28X079 AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101
Crank Case Heater Kit BAYCCHT300 BAYCCHT300 BAYCCHT300 BAYCCHT302
Hard Start Kit Scroll BAYKSKT260
Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004
Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002
Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001
Refrigerant Lineset 5 TAYREFLN950 TAYREFLN7* TAYREFLN7* TAYREFLN7*
General Data
A-WeightedSoundPowerLevel[dB(A)]
MODEL
SOUNDPOWER
LEVEL[dB(A)]
A_WEIGHTEDFULLOVTAVESOUNDPOWERLEVELdB-[dB(A)]
63 125 250 500 1000 2000 4000 8000
4TTB4018E 79 24.9 44.9 56.7 71.1 74.1 72.7 62.2 49.9
4TTB4024E 79 23 45.4 57 70.9 74.2 70.5 62.9 52.6
4TTB4030E 80 27.9 52.9 62.9 74.3 76.2 73 64.7 52.5
4TTB4036E 78 23.2 51.7 64.2 72.3 74.1 71.3 62.7 49.5
4TTB4042E 80 22.8 52.8 65.6 73.3 75.1 75.1 62.8 50
4TTB4048E 80 22.8 52.8 65.6 73.3 75.1 75.1 62.8 50
4TTB4049E 76 44.3 53.8 56.6 63.6 34.6 59.9 52.7 43.7
4TTB4060E 80 22.8 52.8 65.6 73.3 75.1 71.5 62.8 50
4TTB4061E 76 42.2 53.8 57.8 66 65.7 57.7 58.4 51.7
Note:RatedinaccordancewithAHRIStnadard270-2008
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification
program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
. (
denotes
latest revision)
4 For accessory description and usage, see pages 5 and 6.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.