ClimaDry Whole House Dehumidication - ClimateMaster Geothermal Heat Pumps - Rev.: 18 April, 2008B
10
Table 6: Tranquility
20™ (TS) Series PSC Blower Performance Data
(Without ClimaDry)
Model
Fan
Speed
Rated
Airow
Min
CFM
Airow (cfm) at External Static Pressure (in. wg)
0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.60 0.70 0.80 0.90 1.00
018
HI 600 450 704 708 711 702 693 692 690 683 675 658 640 598 515
MED 600 450 602 601 599 590 581 583 585 579 573 560 547 492
LOW 600 450 531 529 527 522 517 512 506 501 495 479 462
024
HI 850 600 965 960 954 943 931 923 914 898 882 862 842 794 725 635
MED 850 600 841 833 825 817 809 800 790 777 763 747 731 686 623
LOW 850 600 723 715 707 703 698 689 680 668 656 642 627
030
HI 950 750 1271 1250 1229 1207 1185 1164 1143 1118 1093 1061 1029 953 875 753
MED 950 750 1048 1037 1025 1016 1007 994 981 962 943 915 886 822
LOW 950 750 890 887 884 879 874 865 855 842 829 809 789
036
HI 1250 900 1411 1407 1402 1390 1378 1370 1361 1326 1290 1248 1205 1083 942
MED 1250 900 1171 1164 1156 1145 1133 1113 1092 1064 1035 997 958
LOW 1250 900 983 967 950 943 936 936
042
HI 1400 1050 1634 1626 1618 1606 1594 1583 1571 1539 1507 1464 1420 1265 1078
MED 1400 1050 1332 1323 1314 1298 1282 1263 1243 1206 1169 1115 1060
LOW 1400 1050 1130 1109 1088 1086 1084 1066 1048 1052 1055
048
HI 1600 1200 1798 1781 1764 1738 1711 1688 1665 1630 1595 1555 1514 1420 1239
MED 1600 1200 1384 1382 1379 1375 1371 1356 1341 1318 1294 1261 1227
LOW 1600 1200
060
HI 1950 1500 2311 2306 2300 2290 2279 2268 2257 2233 2209 2175 2140 2088 1990 1901 1856 1752
MED 1950 1500 2058 2049 2039 2028 2016 2000 1983 1966 1949 1935 1920 1874 1807 1750 1670 1582
LOW 1950 1500 1868 1863 1858 1858 1858 1848 1838 1822 1806 1799 1792 1749 1699 1636 1570
070
HI 2100 1800 2510 2498 2486 2471 2455 2440 2424 2401 2377 2348 2318 2247 2161 2078 1986 1855
MED 2100 1800 2171 2167 2162 2162 2162 2158 2153 2135 2117 2101 2085 2024 1971 1891 1823
LOW 2100 1800 2010 2008 2006 2006 2006 2006 2006 1992 1977 1962 1947 1892 1851
Black areas denote ESP where operation is not recommended.
Units factory shipped on medium speed. Other speeds require eld selection.
All airow is rated and shown above at the lower voltage if unit is dual voltage rated, e.g. 208V for 208-230V units.