: IEC standard
Indoor unit 1 RAV-SM 562MUT-E 562MUT-E
Model
Indoor unit 2 RAV-SM 562MUT-E 562MUT-E
Indoor unit 3 RAV-SM 562MUT-E 562MUT-E
Outdoor unit RAV-SP
1604AT8-E 1604AT7
1604AT8-TR
Cooling capacity (kW) 14.0 (2.6-16.0) 14.0 (2.6-16.0)
Heating capacity (kW) 16.0 (2.4-19.0) 16.0 (2.4-19.0)
Power supply
3 phase 4wired (3N-4pole) 3 phase 4wired (3N-4pole)
380V - 415V 50Hz 380V 60Hz
Running current (A) 8.39 - 7.68 8.39
Power consumption (kW) 4.99 4.99
Cooling Power factor (%) 90 90
EER 2.81 2.81
Electrical
Energy efficiency class C—
Running current (A) 7.77 - 7.11 7.77
characteristics
Power consumption (kW) 4.60 4.60
Heating Power factor (%) 90 90
COP 3.48 3.48
Energy efficiency class B—
Maximum current (A) 15.4 15.4
Indoor unit
Main unit Zinc hot dipping steel plate
Appearance
Ceiling panel
Model RBC-UM11PG(W)-E
(Sold separately)
Panel color Moon-white ( Muncel 2.5GY 9.0/0.5 )
Height (mm) 268 268
Main unit Width (mm) 575 575
Outer dimension
Depth (mm) 575 575
Ceiling panel
Height (mm) 27 27
Width (mm) 700 700
(Sold separately)
Depth (mm) 700 700
Total weight
Main unit (kg) 16 16
Ceiling panel (Sold separately) (kg) 3 3
Heat exchanger Finned tube
Fan Turbo fan
Fan unit Standard air flow H/M/L (m³/min) 13.3 / 11.2 / 9.1 13.3 / 11.2 / 9.1
Motor (W) 60 60
Sound pressure level H/M/L (dB•A) 43 / 39 / 34 43 / 39 / 34
Sound power level H/M/L (dB•A) 58 / 54 / 49 58 / 54 / 49
Connecting pipe Drain port VP25
Outdoor unit
Standard length (m) 7.5 7.5
Min. length (m) 3 3
Outer dimension
Max. total length (m) 50 50
Over 30m 40g/m (31m to 50m)
Hight difference
Outdoor lower (m) 30 30
Outdoor high (m) 30 30
Gas side
Main (mm) 15.9 15.9
Connecting pipe
Sub (mm) 12.7 12.7
Liquid side
Main (mm) 9.5 9.5
Sub (mm) 6.4 6.4
Fan Propeller fan
Fan unit Standard air flow high (m³/min) 103 103
Motor (W) 100 + 100 100 + 100
Sound pressure level Cooling/Heating (dB•A) 51/53 51/53
Sound power level Cooling/Heating (dB•A) 68/70 68/70