Toshiba RAS-B13SKVP-E Air Conditioner User Manual


 
– 67 –
10-5. Test Operation
10-5-1. Gas Leak Test
Check the flare nut connections for gas leaks with
a gas leak detector and/or soapy water.
Fig. 10-5-1
10-5-2. Test Operation
To test the system, push and hold RESET button for
10 sec. (There will be one short beep.)
Fig. 10-5-2
10-5-3. Auto Restart Setting
This product is designed so that, after a power
failure, it can restart automatically in the same
operating mode as before the power failure.
Information
The product was shipped with Auto Restart
function in the OFF position.
Turn it ON as required.
How to Set the Auto Restart
Push and hold the RESET button for about 3
seconds. After 3 seconds, three short electric
beeps will be heard to inform you that the Auto
Restart has been selected.
To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function on
Owner’s Manual.
10-5-4. If the air conditioner operates
incorrectly
If two indoor units are installed in the same room
or adjoining rooms, when the user tries to operate
only one unit, both units may receive the same
remote controller signal and operate. This can be
prevented by changing one of the indoor units and
remote controllers to setting “B”
(The default setting for both units is “A”).
If the indoor unit and remote controller settings
are different, the remote controller signal is not
accepted.
1. Setting the remote controller
1) Slide open the remote controller cover and
remove the batteries.
2) Cut the jumper wire inside the battery
compartment using nippers.
The jumper wire should not remain in
contact after being cut. Also, be careful
not to let plastic scraps, jumper wire
cuttings or other debris enter the inside of
the remote controller.
3) Insert the batteries. “B” appears in the
remote controller display.
2. Setting the unit
Push the RESET button to start automatic
operation.
3. Push the button of the remote controller
that was set in step 1 to stop the air
conditioner.
(This operation will change the setting to “B”.)
4. Check that the remote controller operates the
indoor unit.
Check places for
flare nut connections
(indoor unit)
Check places
for outdoor unit
Valve cover
Electric parts
RESET button
RESET
FILTER TIMER PURE OPERATION
Fig. 10-5-3
Fig. 10-5-4
RESET
FILTER TIMER PURE OPERATION
RESET button
When switching between settings A and
B , always switch the indoor unit board
and the remote controller as a pair.
(Otherwise, the indoor unit will not
accept the remote controller s signals.)
Cutting direction
Jumper wire
CLOCK
CHECK
RESET
CLR
SET
SWING
FIX
FAN
ON
OFF
HiPOWER
SLEEP MODE
MEMO
OFF
1
.
3
.
5
.
9H