14. SET UP OF SERVICE P.C. BOARD
Before replacing the P.C. board, set up the P.C. board according to the following table.
Caution
When repaired P.C. board should be electric discharge of capacitor. (C12, C13, C14)
APPLICATION MODELS :
RAS-10SAVP-E, RAS-13SAVP-E, RAS-16SAVP-E
RAS-10SAVP-ND, RAS-13SAVP-ND, RAS-16SAVP-ND
JUMPER SET UP :
As shown in the following table, cut jumper lead wire (J800, J801, J802, J806) according to each model.
LOCATION OF JUMPER LEAD WIRE :
Corresponding
model
Jumper lead wire
J800
Jumper lead wire
J801
Jumper lead wire
J802
Jumper lead wire
J806
ORIGINAL
RAS- RAS- RAS- RAS- RAS- RAS-
10SAVP-E 13SAVP-E 16SAVP-E 10SAVP-ND 13SAVP-ND 16SAVP-ND
Close Close Close Open Open Close Close
(Original) (Original) (Original) (Cut) (Cut) (Original) (Original)
Close Close Open Close Open Close Open
(Original) (Original) (Cut) (Original) (Cut) (Original) (Cut)
Close Close Close Close Close Open Close
(Original) (Original) (Original) (Original) (Original) (Cut) (Original)
Close Close Close Close Close Close Close
(Original) (Original) (Original) (Original) (Original) (Original) (Original)