– 25 –
6-2. Outdoor Unit
RAS-M14EAV-E, RAS-M14EACV-E, RAS-M18EAV-E, RAS-M18EACV-E
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Rating
AC 250V, 20A, 0.15mH
AC 250V, 20A, 0.88mH
Primary side DC 280VSecondary side:
7.5V x 1, 13V x 126.5V x 3, 16V x 1, 15V x 1
DC 140V, 43W
Coil: DC 12V, Contact: 2A, AC250V
Coil: DC 12V, Contact: 20A, AC250V
64kΩ (20°C)
10kΩ (25°C)
64kΩ (25°C)
64kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
10kΩ (25°C)
20A, AC 250V
3.15A, AC 250V
25A, AC 25V
6.3A, AC 250V
DC 400V, 760µF
600V, 20A
3 phases, 4 poles, 1,100W
3 phases, 4 poles, 750W
OFF: 125±4°C, ON: 90±5°C
Diode: 600V, 25A
IGBT: 600V, 40A
L = 10mH, 16A
L = 10mH, 1A
Model name
ADR2520-R15TB or SC-20-01J-A
ADR25H-200R8TB
SWT-72 or SWT-83
ICF-140-43-4
G5N-1A
DI12D1-O or G4A-1A-PE
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
—
For protection of switching power source (F03)
For protection of inverter input overcurrent
For protection of power source
LLQ2G761KHU
GT20J321
DA130A1F-25F
DA111A1F-20F1
US622KXTMQO
D25 X B60
GT40Q321 or GT30J121
CH-57
CH-43-Z-K
Parts name
SC coil (Noise filter) (L03)
SC coil (Noise filter) (L01)
DC-DC transformer
Outside fan motor
Relay (4-way valve)
Relay (Power relay)
Discharge temp. sensor (TD-sensor)
Outside air temp. sensor
(TO-sensor)
TGa-sensor (Heat pump models)
TGb-sensor (Heat pump models)
TGa-sensor (Cooling-only models)
TGb-sensor (Cooling-only models)
Evaporator temp. sensor
(TE-sensor)
Suction temp. sensor (TS-sensor)
Terminal block (9P)
Fuse
Electrolytic capacitor
IGBT (Q200~Q205)
Compressor (M18)
Compressor (M14)
Compressor thermo.
Rectifier (DB01, DB02)
IGBT (Q404)
Reactor (Main)
Reactor (Sub)
NOTE: *1 Heat pump models only.
*1
*1