2. SPECIFICATIONS
6
Unit model Indoor RAS-15LKV-UL RAS-17LKV-UL
Outdoor RAS-15LAV-UL RAS-17LAV-UL
Cooling capacity (Btu/h) 15000 16200
Cooling capacity range (Btu/h) 2750 - 17050 3750 - 20450
Heating capacity (Btu/h) 18000 20200
Heating capacity range (Btu/h) 2750 - 21500 2750 - 21500
Power supply
Electric Indoor Operation mode Cooling Heating Cooling Heating
characteristic Running current (A) 0.32 - 0.29 0.32 - 0.29 0.32 - 0.29 0.32 - 0.29
Power consumption (W) 40 40 40 40
Power factor (%) 60 60 60 60
Outdoor Operation mode Cooling Heating Cooling Heating
Running current (A) 5.43 - 4.91 6.65 - 6.01 6.13 - 5.51 7.78 - 7.01
Power consumption (W) 1110 1360 1245 1590
Power factor (%) 98 98 98 99
Starting current (A) 5.75 - 5.20 6.97 - 6.30 6.45 - 5.80 8.10 - 7.30
EER (Cooling/Heating) (Btu/W.h) 13.00 12.80 12.60 12.40
SEER (Btu/W.h) / HSPF (W/W)
Operating Indoor High (Cooling/Heating) (dB-A) 44/44 47/47
noise Medium (Cooling/Heating) (dB-A) 38/39 41/42
Low (Cooling/Heating) (dB-A) 32/32 35/35
Outdoor (Cooling/Heating) (dB-A) 51/51 52/52
Indoor unit Unit model RAS-15LKV-UL RAS-17LKV-UL
Dimension Height in. (mm) 12-19/32 (320) 12-19/32 (320)
Width in. (mm) 41-5/16 (1050) 41-5/16 (1050)
Depth in. (mm) 8-15/16 (228) 8-15/16 (228)
Net weight lbs (kg) 29 (13) 29 (13)
Fan motor output (W) 30 30
Air flow rate (Cooling/Heating)
cfm (m
3
/min)
562 (15.9)/583 (16.5) 636 (18.0)/646 (18.3)
Outdoor unit Unit model RA S-15LAV-UL RAS-17LAV-UL
Dimension Height in. (mm) 21-11/16 (550) 21-11/16 (550)
Width in. (mm) 30-11/16 (780) 30-11/16 (780)
Depth in. (mm) 11-7/16 (290) 11-7/16 (290)
Net weight lbs (kg) 91 (41) 91 (41)
Compressor Motor output (W) 1100 1100
Type
Model DA130A1F-27F1 DA130A1F-27F1
Fan motor output (W) 43 43
Air flow rate (Cooling/Heating)
cfm (m
3
/min)
1282 (36.3)/1127 (31.9) 1636 (38.6)/1127 (31.9)
Piping Type Flare connection Flare connection
connection Indoor unit Liquid side in. (mm)
1/4 (
6.35)
1/4 (
6.35)
Gas side in. (mm)
1/2 (
12.70)
1/2 (
12.70)
Outdoor unit Liquid side in. (mm)
1/4 (
6.35)
1/4 (
6.35)
Gas side in. (mm)
1/2 (
12.70)
1/2 ( 12.70)
Maximum length ft. (m)
Maximum chargeless length ft. (m) 49 (15) 49 (15)
Maximum height difference ft. (m) 33 (10) 33 (10)
Refrigerant Name of refrigerant R410A R410A
Weight lbs (kg) 3.09 (1.40) 3.09 (1.40)
Wiring Power supply
connection Interconnection 4Wires:includes earth 4Wires:includes earth
Usable temperature range Indoor (Cooling/Heating) °F (°C) 70°F-90°F (21°C-32°C)/ 32°F-82°F (0°C-28°C)
Outdoor (Cooling/Heating) °F (°C) 14°F-115°F (-10°C-46°C) / 5°F-75°F (-15°C-24°C)
* The specifications may be subject to change without notice for purpose of improvement.
1Ph, 60Hz, 208V/230V 1Ph, 60Hz, 208V/230V
3Wires:includes earth (Outdoor) 3Wires:includes earth (Outdoor)
20.0/9.0
66 (20)
19.0/9.0
66 (20)
Twin rotary type with DC-inverter
variable speed control
Twin rotary type with DC-inverter
variable speed control
2-1. Specifications (RAS-15LKV-UL/RAS-15LAV-UL, RAS-17LKV-UL/RAS-17LAV-UL)