Item
13. Self-Cleaning
Operation flow and applicable data, etc.
1. Purpose
The Self-Cleaning operation is to minimize the
growth of mold, bacteria etc. by running
the fan and drying so as to keep the
inside of the air conditioner clean.
Self-Cleaning operation
When the cooling or dry operation shuts
down, the unit automatically starts the Self-
Cleaning operation which is then performed
for the specified period based on duration
of the operation which was performed
prior to the shutdown, after which the
Self-Cleaning operation stops.
(The Self-Cleaning operation is not
performed after a heating operation.)
2. Operation
1) When the stop signal from the remote
controller or timer-off function is received,
only the timer indicator light.
2) The period of the Self-Cleaning operation
is determined by the duration of the
operation performed prior to the
reception of the stop code.
3) After the Self-Cleaning operation has
been performed for the specified period,
the unit stops operating.
Unit now performing cooling or dry operation
Press “STOP” button
Only timer indicator lights, and Self Cleaning operation starts
Time set now elapses
Operation stops
function
During Self-Cleaning operations: The louver opens
slightly. The indoor fan operates continuously at
a speed of 500 rpm.
Cooling: Auto (cooling) Dry
Heating: Auto (heating)
Auto (fan only)
Shutdown
Operation time
Up to 10 minutes
No Self-Cleaning operation
performed (0 minutes)
10 minutes
30 mins.
or longer
No Self-Cleaning operation performed
To stop an ongoing Self-Cleaning operation at any time
Press the start/stop button on the remote controller twice during the Self-Cleaning
operation. (After pressing the button for the first time, press it for the
Self-Cleaning operation times
second time without delay (within 10 minutes).)
Description
Self-Cleaning operation time