Toshiba HWS-2101CSHM3-E(-UK) Heat Pump User Manual


 
16
Toshiba
*1Heating performance measurement conditions: outside air temperature 7 or 6 °C, water supply temperature 30 °C, outlet temperature 35 °C, refrigerant piping length 7.5 m (no height
difference), capacity 97%, COP 95%, operating noise +3 dB
*2Cooling performance measurement conditions: outside air temperature 35 °C, water supply temperature 12 °C, outlet temperature 7 °C, refrigerant piping length 7.5 m (no height
difference), capacity 97%, COP 95%, operating noise +3 dB
*3• The remote controller should be shipped with the hydro unit.
• Use two 1.5-meter wires to connect the hydro unit with the remote controller.
*4The outdoor unit operating noise is measured at the point of 1m away from the unit back surface center and 1m high from the ground. The hydro unit operating noise is measured at the
point of 1m away from the unit front surface center.
The value of the operating noise varies depending on room structure where the unit is installed.
*5Do not leave the hydro unit at 5 °C or below.
*6Check the water piping for leakage under the maximum operating pressure.
Unit name Hydro unit HWS-1402XWHM3-E, 1402XWHT6-E, 1402XWHT9-E
Outdoor unit HWS-1102H-E HWS-1402H-E
Heating capacity *1 (kW) 11.2 14.0
Cooling capacity *2 (kW) 10.0 11.0
Variable range of compressor frequency 10 - 60Hz 10 - 70 Hz
Power source Single phase 50Hz 230V
Operation mode Heating Cooling Heating Cooling
Electric characteristic *1 *2 Hydro unit Current (A) 0.63 0.61 0.67 0.63
Power (kW) 0.135 0.130 0.145 0.135
Power factor (%) 93.2 92.7 94.0 93.2
Outdoor unit Current (A) 10.14 14.88 13.57 17.47
Power (kW) 2.265 3.39 3.005 3.945
Power factor (%) 96.9 99.1 96.4 98.1
Total Starting current (A) 10.77 15.49 14.24 18.10
Operating noise *1 *2 *4 Hydro unit (dB(A)) 29 29 29 29
Outdoor unit (dB(A)) 49 49 51 51
Coefficient of performance *1 *2 4.66 2.84 4.45 2.69
Hydro unit Outer dimension Height (mm) 925
Width (mm) 525
Depth (mm) 355
Net weight (kg) 54
Color Silky shade (Munsell 1Y8.5/0.5)
Remote controller
Outer dimension *3
Height (mm) 120
Width (mm) 120
Depth (mm) 20
Circulating pump Motor output (W) 190 (MAX)
Flow rate (L/min) 32.1 28.9 40.1 31.5
Type Non-self-suction centrifugal pump
Heat exchanger Plate-type heat exchange
Outdoor unit Outer dimension Height (mm) 1340
Width (mm) 900
Depth (mm) 320
Net weight (kg) 90
Color Silky shade (Munsell 1Y8.5/0.5)
Compressor Motor output (W) 2500
Type Twin rotary type with DC-inverter variable speed control
Model DA422A3F-25M
Fan motor Standard air capacity (m
3
/min) 103.0
Motor output (W) 100 × 2
Refrigerant piping Connection method Flare connection
Hydro unit Liquid Ø9.52
Gas Ø15.9
Outdoor unit Liquid Ø9.52
Gas Ø15.9
Maximum length (m) 30
Maximum chargeless length (m) 30
Maximum height difference (m) ±30
Minimum length (m) 3
Refrigerant Refrigerant name R410A
Charge amount (kg) 2.7
Water piping Pipe diameter R1 1/4
Maximum length (m) None (Need the flow rate 13 /min or more)
Maximum height difference (m) ±7
Maximum working water pressure (kPa) 300
Operating temperature range Hydro unit (°C) 5-32
Outdoor unit (°C) -20-43
Operating humidity range Hydro unit (%) 15-85
Outdoor unit (%) 15-100
Wiring connection Power wiring 3 wires: including ground line (Outdoor unit)
Connecting line 4 wires: including ground line
+00A09-002_01EN_SVM_ALL_Air_to_Water.book Page 16 Monday, October 5, 2009 2:09 PM