Lide Glass Lid J3500 Stove User Manual


 
36
NEW AIR WASH SYSTEM FOR COUNTRYSIDE UNITS
NOTE: These adjustments should only be made by a qualified technician
The new air wash system is an integral part of the firepot system. This will enable the unit to perform better under negative air
pressure situations in the home. The Air Wash Bracket (B) needs to be adjusted to within 1/16”- 1/8” away from the glass
surface. To do this you must loosen the two (2) ¼” nuts (A) and slide the bracket in the direction that is needed. Be sure to
tighten the nuts securely but not too tight to that they break.
NOTE: If you adjust the Air Wash Bracket too close to the glass you will not get adequate air wash and you could break the
glass
. Do not close the door fast. Check to make sure the bracket clears the glass
If you take the Firepot out of the Firepot Cradle you will see two (2) ¼” nuts located toward the bottom front side of the firepot
cradle. If you want to reduce the amount of air that is directed to the air wash and re-direct it into the firepot you need to
loosen the nuts and slide the nuts toward the outer sides of the firepot cradle. Be careful not to close them too much or it will
make the glass dirty and the fire might go out on the lower heat settings. It is best to leave the plates wide open as they are
shipped from the factory. Be careful not to over tighten the nuts and twist them off. They cannot be replaced.
A
B
¼” nuts, slide to outside to close,
slide to inside to open