Lide Glass Lid 3500P Stove User Manual


 
26
MAINTENANCE INSTRUCTIONS CONTINUED…
9 While you are tapping the side heat exchangers, we recommend that you pull the draft knob all the
way out for a minute or two and put the unit on high fire. This will allow the unit to self-clean the
heat exchanger area, the draft fan and exhaust chimney pipe.
9 If a clinker ball develops in the firepot, scrape it out with the clean-out. You may have to do this once
or twice a day depending on the moisture content of the corn. If this is not cleaned out, it could cause
the fuel stirrer to jam. Clinker balls are a direct result of excessive corn moisture and they do not
indicate a problem with the stove. AES highly recommends an additive called “Clean Burn” be added
to your corn to eliminate these clinkers. Contact your local Countryside reseller for availability and
cost.
9 Open the stove doors and wipe the inside of the glass with a damp cloth as needed.
SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS:
3500P & 3500L Models: After cleaning or when operating the model 3500P & 3500L models you need to
make sure that the clean-out plates are in the closed position. Push the front (2) clean-out slides all the
way in and make sure that you have replaced the left & right clean-out plates that are located on the inside
of the unit. (These plates are located inside the firebox to the left and right of the firepot in the lower
corners of the firebox.) If these plates are not in the closed position the unit will burn dirty.
3502 Insert Models: After cleaning or when operating the model 3502 models you need to make sure that
the clean-out plates are in the closed position. There are (2) two sets of clean-out plates that need to be
closed. The first set is to the left and right of the firepot inside the firebox. These plates need to be slid
closed after cleaning out the fly-ash. The second set of clean-out plates are located inside of the ash pan
area below the firepot. Open the ash pan, clean out all the ash, slide the plates toward the center of the
firebox to open and scrape out the ash from behind the back wall of the unit. Slide the plates closed and
replace the ash pan. Make sure to lock the ash pan in place.
All models have clean-out
plates located inside the door
in the lower left and right
corners of the firebox.
3502 models have clean-out
plates located in the back right &
left corners inside the ash pan
area. Make sure that these are
closed when operating the unit.
Make sure that the ash pan is
locked in place.
All models have a heat exchanger
tube cleaning rod to clean once a
week
3500P & 3500L models have (2)
front cleanout slides that must be
in the closed position when
burning the unit.