Sterling 90-225 CFM Dehumidifier User Manual


 
Cabinet Series Dehumidifying Dryer 44
Initialize
Setup
6UE1 Control Output 1
Assignment
Heat/Cool/Alarm 1/Alarm 2/Alarm 3/
LBA
Heat Default
Setup
6UE2 Control Output 2
Assignment
Heat/Cool/Alarm 1/Alarm 2/Alarm 3/
LBA
AL-1 Default
Setup
Sub 1 Auxiliary Output
1 Assignment
Alarm 1/Alm 2/Alm 3/LBA/S.ERR/E333 AL-1 Default
Setup ALE1 Alarm 1 Type 0 to 11 2 Default
Setup
AL1n Alarm 1 open in
alarm
NO/NC NO
Default
Setup ALE2 Alarm 2 Type 0 to 11 2 Default
Setup
AL2n Alarm 2 open in
alarm
NO/NC NO Default
Setup ALE3 Alarm Type 0 to 11 2 Default
Setup
AL3n Alarm 3 open in
alarm
NO/NC NO Default
Setup
6rEu Direct/Reverse
Operation
OR-R/OR-D OR-R Default
Mode Parameter Setting range
Default
Factory
setting
Expansion
SL-H Set Point Upper
Limit
SP Lower Limit +1 to Scaling Upper
Limit
1300 400.0
Expansion
SL-L Set Point Lower
Limit
Scaling Upper Limit to SP Lower Limit -200 0
Expansion CnEL PID/ON/OFF PID/ON/OFF PID Default
Expansion
SE ST Adaptive Tuning
(Fuzzy)
OFF/ON OFF Default
Expansion SE-b ST Stable Range
0.1 to 999.9 °C/F
15 Default
Expansion
ALFA α
0.01 to 1.00 0.65 Default
Expansion
AE-G AT Calculated
Gain
0.1 to 10.0 1.0 Default
Expansion
rESE Standby
Sequence Reset
Setting Method
0/1 0
Default
Expansion
rEE Automatic Return
of Display Mode
0 to 99 SEC 0 Default
Expansion AE-H AT Hysteresis 0.1 to 9.9% FS 0.2 Default
Expansion
LbAb LBA Detection
Width
0.0 to 999.9% FS 0.2 Default
Option Boards
Available Option Boards