Spectra Watermakers Newport 400 Water System User Manual


 
16
Install the Nut first then use the bevelled side of the Spacer to push the
Grab Ring onto the tube no more than 1/2". Slip the O-ring over the tube
to hold the Spacer in place. If the Grab Ring is pushed too far, trim back
the tube so about 1/4" of tube extends past the O-ring.
Use 2 grab rings for 1/2" tube
Single grab ring for 1/4" & 3/8" tube
1/2" tube should not bottom out in the fitting
to allow full compression of the O-ring
Hand tighten the nut. DO NOT OVER TIGHTEN!
DO NOT USE A WRENCH! The tube should not
come out if pulled by hand. If it does, tighten the
1/4", 3/8", 1/2" Parker Tube Fitting Assembly
Gently fit the tube into the body and loosely thread on the nut.
Be careful not to cross-thread the nut
grab ring tabs.
Step 4:
Step 3:
Step 1: Dissemble fitting components
O-ring
Step 2:
Body
Spacer
Tubing
1/2" max
Nut
Parker Tube Fitting Assembly Procedure