PRODUCT SPECIFICATIONS
ITEM #
SG-DEH-70EP-2
Moisture Removal per 24 hours
70 Pints per day
(32.9 Liters per day)
Power Consumption (W) 745 Watts
Bucket Capacity 17 Pints (8 Liters)
Power Source 115 V / 60 HZ
Rated Current (Amps) 7.3A
Sound Pressure Level dB (L/M/H) 45/47/49 dB(A)
Weight 47.7 lbs
D
imensions (W x D x H) 15.125” x 11.5” x 24.125”
Error Code
Error Type Possible Cause Corrective Action
F1
Ambient Tem-
perature Sensor
Malfunction
1. Unplug the dehumidifier.
2. Check the surrounding area for
possible reasons for sudden
temperature changes.
3. Wait 30 minutes before plug-
ging the dehumidifier back in
for normal operation.
4. If the “Error” is still indicated,
please contact your nearest
service center. Call (888) 876-
5387 for service center
locations.
F2 Pipe Tem-
perature
Sensor Mal-
function
1. Sudden Change in
the surrounding
temperature.
2. Faulty Sensor
ERROR CODES
5
To reduce the risk of fire, electric shock or injury to persons, read the important SAFETY IN-
STRUCTIONS found on page 3 before operating this appliance.
KEY FEATURES
WARNING
CHOOSING THE PROPER LOCATION
Use the dehumidifier:
in the basement to help prevent moisture
damage.
in the kitchen, laundry room, bathroom,
and spa/exercise areas that have exces-
sive moisture.
to prevent moisture damage anywhere
books or valuables are stored.
during construction or remodeling to
reduce drying time for drywall and paint.
However, check and clean filter often.
AUTOMATIC SHUT OFF
When the bucket is full, or when the
bucket has been removed, the compres-
sor will automatically stop. The fan will
continue to run to dehumidify for 3 min-
utes. Then the Bucket Full indicator will
flash and you will hear a ten second
audible alarm.
The bucket must be placed in the proper
position for the dehumidifier to work.
The Bucket Full light will flash and the
dehumidifier will not run if the bucket is
not in the proper position. Dehumidifier
settings can not be changed when the
bucket is not in its proper position.
The dehumidifier fan will shut off in 3
minutes, once the desired
Washable Filter
Enclosure
Continuous Drain
Connector Door
Power Cord
Caster
Bucket
3 ft.
Dehumidifier
Hose
16 ft. Pump
Drain Hose
Power Cord
Dehumidifier
Vertical
Pump
Reference Number
DP2-70EP-03
tive Humidity (RH).
humidity
ting is reached plus or minus 5% Rela-
set-