11
MAINTENANCE
Note: Make sure power is off and the plug is pulled out of the power outlet before
performing any maintenance activities.
1)
Clean or replace filter
If the air filter is blocked with a lot of dust, the airflow volume will reduce. It is recommended
to clean the filter once every two weeks or as needed.
a) Pull up the filter from the filter compartment in the back of the unit.
b) Wash the air filter by immersing it gently into warm (about 104 F) water with a neutral
detergent. Rinse the filter and dry it thoroughly in a shaded place.
c) Replace the filter back to the filter compartment after it is thoroughly dried.
a) If the filter is torn or unusable, order a new filter by calling the contact section of this
manual.
2)
Case
a. Keep the unit from being exposed directly to the sun for possible color
fading.
b. Clean the surface with a damp cloth. Dry it with a soft towel.
3)
Storing the Unit for an Extended Period of Time or Transporting
a) Empty water by unplugging the water drainage stop at the back
towards the bottom of the unit
b) Unplug the unit.