Exhaust Duct
Window Kits
INSTALLATION BEFORE USE
Binary Hose Design
Note: When you using the unit for cooling, heating or as a dehumidifier, the outdoor air
must be directed to the unit and the hot air must be exhausted out of the room to complete
the air exchange. When the unit is operating on fan mode, no outdoor air exchange takes
place. You do not need to hookup the window kits and exhaust hose when you use the unit
as a fan.
1)
Single Hose Installation: (1 exhaust duct required)
For fast spot cooling, use this installation.
a) Pull out of both ends of the exhaust ducts for approximately 6”.
b) Screw clockwise the exhaust ducts with one end to the terminal end and other end
to the window kit adapter.
c) Remove only one exhaust outlet wall cover from the back of the unit by screwing
the covers counter-clockwise before lifting it up and leave the second wall cover