◆Specification and Technical Data
Model
KFIHP-09-ID
KFIHP-09-OD
KFHHP-12-ID
KFHHP-12-OD
Function Cool / Heat
Accessory Air Cleaner
Cooling capacity (Btu/h) 9000 12000
Heating capacity (Btu/h) 9500 13000
Power Supply (V) 115V~ 208~230
Frequency (Hz) 60
Cooling/Heating rated current(A) 12/13.6 9/10
Cooling/Heating rated power(W) 1250/1450 1700/1750
Cooling/Heating power input(W) 730/840 1100/1200
Recycling air Volume(
m
3
/h
)
550
Refrigerant and weight(lbs)
R410A 2.6 lbs R410A 2.8 lbs
Water proof level IP24
Noise(Indoor/Outdoor)dB(A) 43/55
Climate type T1
Anti-electric shock protection I
Weight Indoor/Outdoor)(lbs) 24.3/99.2 24.3/99.2
Dimensions
(W x D x H)
Indoor unit
30.31”×7.48”×9.84” 32.68”×8.86”×11.22”
Outdoor unit
33.39”×12.6”×21.26” 33.39”×12.6”×21.26”
Connection Pipe:
Length (ft) 19.68
Gas additional charge(oz/ft) 0.16
Liquid Pipe (mm)
Φ6(1/4”)
Outer Diameter
Gas Pipe (mm)
Φ12(1/2”)
Height (ft) 16.4
Max Distance
Length (ft) 49.21
1. All above are tested and certified to ETL specification.
2. All above could be changed without notice; the latest specifications are on the nameplate of your air conditioner.
3. When the unit is restarted after it stopping, it can automatically resume the last running mode, and the outdoor unit
starts later.
Working temperature range:
Indoor side DB/WB(°F) Outdoor side DB/WB(°F)
Maximum cooling 89.6 / 73.4 109.4 / 78.8
Minimum cooling 69.8 / 59 69.8 / -
Maximum heating 80.6 / - 75.2 / 64.4
Minimum heating 68 / - 23 / 21.2