Smeg PGA64 Stove User Manual


 
Instructions for the installer
33
6.3 Electrical connection
Make sure that the voltage and capacity of the power line conform to the data
shown on the plate located under the casing. Do not remove this plate for any
reason.
The plug at the end of the supply cable and the wall socket must be of the same
type and must conform to the applicable legislation on electrical installations.
Make sure that the supply line is suitably earthed.
Fit power line with an omnipolar circuit breaker with a contact opening gap equal
to or greater than 3 mm in an easily accessible position close to the hob.
Avoid the use of adapters and shunts.
If the power cable is replaced, the cross-
section of wires in the new cable must be
no less than 0.75 mm2 (3 x 0.75 cable),
remembering that the end for connection to
the appliance must have a longer earth
wire (yellow/green)
, longer by at least 20 mm. Only use a H05V2V2-F or similar resistance cable to
the maximum temperature of 90°C. Its replacement must be carried out be a
specialised technician who must carry out the network connection following the
diagram below.
L = brown
N - blue
= yellow/green
The manufacturer cannot be held liable for damage to persons or things caused
by non-observance of the above directions or by interference with any part of the
appliance.