Slant/Fin Oil-Fired Boilers Boiler User Manual


 
Intrepid can provide hot water all year
long for your kitchen, bath and laundry.
Optional high output tankless heater. This coil type “instant” hot water
maker is located inside the boiler where the constant flow of hot boiler water heats
your fresh water as it passes through the coil. Intrepid’s extended coil well accom-
modates a larger coil to maximize output. Recovery is fast and the total capacity
will vary with the boiler size.
Indirect water heaters. If you
prefer to have a larger reserve of hot
water, your installer can provide a hot
water storage tank that is easily
connected to the Intrepid boiler. These tanks typically store
between 20 and 60 gallons of hot water. Some require the
boiler’s tankless heater coil to make hot water. Others have built-
in heating coils which are connected to your boiler in the same
fashion as a heating zone. Your heating contractor can recom-
mend which domestic hot water system is best for your needs.
Zone your heating system for even
greater fuel savings.
By dividing your home into separate heating
zones, you can save energy by heating only
those areas you’re using. Depending on your
existing piping arrangement, it may be quite
simple to zone your system. An auxiliary return
tapping on the Intrepid boiler gives the heating
installer added flexibility in setting up two or
more heating zones in your home.
BOILER
INDIRECT-
FIRED
WATER
HEATER
®
Standard working pressure 30 PSI water,
15 PSI steam.
All boilers hydrostatically tested — A.S.M.E.
STANDARD EQUIPMENT
P PT PPT PZ PZT
Assembled sections x x x x x
Jacket with insulation x x x x x
Target wall * x x x x x
Pressure and temperature gauge x x x
Pressure relief valves (ASME), in carton x x x x x
Flame retention oil burner with nozzle,
primary relay and cadmium sulfide
flame detector x x x x x
Draft regulator, in carton x x x x x
Circulator: 1
1
4" (TR-20 thru TR-40)
1
1
2" (TR-50 thru TR-60)
(No circulator supplied with TR-70) x x x
Drain cock, in carton x x x x x
Flue brush, in carton x x x x x
Combination hi-limit control and
circulator relay (TR-20 thru TR-60) x x
Tankless water heater x x
Provision for tankless water heater x
Cover plate instead of tankless heater x x
Combination hi and low limit control,
circulator relay (TR-20 thru TR-60) x
Hi and low limit control (TR-70) x x
Hi-limit control (TR-70) x
Pressuretrol with siphon, in carton x x
Burner mounting plate with swing out door x x x x x
Burner mounting plate/insulation *
Inspection door x x x x x
Service switch x x x x x
Low water cutoff, No. 67 MM, installed x x
Steam trim, gauge and glass gauge in carton x x
Low limit control x
P Packaged water boiler less tankless heater
PT Packaged water boiler with tankless heater
PPT Packaged water boiler with provision for
tankless heater
PZ Packaged steam boiler less tankless heater
PZT Packaged steam boiler with tankless heater
*All packaged boilers are equipped as shown
in Standard Equipment chart. In addition, the
following models are provided with a blanket
in the combustion area: water models TR-60
and TR-70; steam models TR-30, TR-40, TR-
50, TR-60 and TR-70. All “KD” and “U” boil-
ers are equipped with full combustion cham-
ber, burner mounting plate and insulation,
except that model TR-20 is equipped with
blanket in combustion area.
OPTIONAL EQUIPMENT
Two-stage fuel pump.
Choice of alternate brand circulators and
burners.
TRDV sealed combustion models
For installations
without a chimney,
Intrepid TRDV models
vent directly to the
outdoors. See Pub.
No. TRDV-10.
Note: Basic Intrepid TR-
Series boilers, described in
this literature (Pub.TR-10),
are not designed for direct
vent applications
.