5. Capacity table
SMF-4E27AI (7k+7k+7k+7k)
COOLING OUTDOOR TEMPERATURE DRY
Indoor
Conditions
21ºC 25ºC 30ºC 35ºC 40ºC 45ºC
Total capacity kW 7.63 7.30 7.03 6.64 6.37 6.17
Sensitive capacity kW 6.11 5.84 5.63 5.31 5.10 4.94
21ºC D
15ºC W
Input kW. 1.95 2.23 2.51 2.79 3.07 3.35
Total capacity kW 8.36 7.99 7.70 7.27 6.98 6.76
Sensitive capacity kW 6.69 6.40 6.16 5.81 5.58 5.41
24ºC D
17ºC W
Input kW. 2.06 2.36 2.65 2.95 3.24 3.53
Total capacity kW 9.09 8.69 8.37
7.90
7.58 7.35
Sensitive capacity kW 7.27 6.95 6.70 6.32 6.07 5.88
27ºC D
19ºC W
Input kW. 2.17 2.48 2.79
3.10
3.41 3.72
Total capacity kW 10.45 9.99 9.63 9.09 8.72 8.45
Sensitive capacity kW 8.36 7.99 7.70 7.27 6.98 6.76
32ºC D
23ºC W
Input kW. 2.50 2.85 3.21 3.57 3.92 4.28
HEATING
OUTDOOR CONDITIONS
Indoor
Conditions
24ºC D
18ºC W
12ºC D
11ºC W
7ºC D
6ºC W
4ºC D
3ºC W
0ºC D
-1ºC W
-
5ºC D
-6ºC W
-7ºC D
-8ºC W
-15ºC D
-16ºC W
Capacity
kW
14.66
11.73 9.78 8.80 8.31 7.33 6.84 6.35
15ºC
Input kW. 5.52 4.42 3.68 3.50 3.31 3.13 2.94 2.58
Capacity
kW
13.77
11.02 9.18 8.26 7.80 6.89 6.43 5.97
18ºC
Input kW. 5.18 4.15 3.46 3.28 3.11 2.94 2.76 2.42
Capacity
kW
12.75
10.20
8.50
7.65 7.23 6.38 5.95 5.53
20ºC
Input kW. 4.80 3.84
3.20
3.04 2.88 2.72 2.56 2.24
Capacity
kW
11.73 9.38 7.82 7.04 6.65 5.87 5.47 5.08
22ºC
Input kW. 4.42 3.53 2.94 2.80 2.65 2.50 2.36 2.06
Capacity
kW
10.20
8.16 6.80 6.12 5.78 5.10 4.76 4.42
27ºC
Input kW. 3.84 3.07 2.56 2.43 2.30 2.18 2.05 1.79