Simer Pumps 2110 Water Pump User Manual


 
Repair Parts / Troubleshooting 4
For parts or assistance, call Simer Customer Service at 1-800-468-7867 / 1-800-546-7867
TROUBLESHOOTING
Risk of electrical shock and sudden start.
Disconnect electrical power to pump before attempting to troubleshoot or work on it.
REPAIR PARTS
1
2
3
5
5A
4
6
Key Part Description Qty. 2110-01
1 Handle Screw 2 670-646
2 Power Cord (8 ft.) 1 227-264-B-TSU
3 Handle 1 383-147-B
4 Motor 1 **
5Volute Assembly 1 404-160
5A Pump Screen 1 *
6Volute Screw 6 670-646
* Included in Key Item 5.
** If the motor fails, replace the entire pump.
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Pump won’t Blown fuse If blown, replace with fuse of proper size
start or run
Low line voltage If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company
Defective motor Replace pump
Clogged screen Remove volute, clean the screen and replace the volute
Pump operates Low line voltage Use only 14 gauge or larger extension cords. Use short extension cords
but delivers little when necessary
or no water
Small diameter garden hose Use larger diameter garden hose or 1” flexible pipe. Eliminate any
or long discharge line excess hose. Short hoses work best
Check valve installed without Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump
vent hole discharge & check valve
Coils or bends in hose Straighten hose