Sigma AS-H60Y Heat Pump User Manual


 
11
When the ON/OFF buttons is pressed for the first time, the display
panel will display the current water temperature and the desired pool
temperature.
eg. the display may read 10 40 ----- 10 is the current water
temperature 10°C and 40 is the desired water temperature 40°C.
ADJUSTING THE POOL WATER TEMPERATURE
Using the up and down buttons, you can set the swimming pool water
to the desired temperature between +15°C up to + 65°C.
When the SET button is used for the first time, the display panel will
display
F1-this is to set the temperature differential. The
recommended setting is 2°C. To adjust setting YOU MUST PRESS
THE ON/OFF BUTTON FIRST. Then use the UP and DOWN button to
set the differential temperature range between 0 °C ~ 5°. Press on/off
button again to take you back to the normal display. The unit will now
stop working when the swimming pool water temperature reaches the
setting temperature. The unit will automatically restart when the
swimming pool water temperature drops below the setting temperature.
Eg. If current pool water temperature is 20°C, F1 has been set to 02
(heating mode) when the temperature reaches 20°C the heater will stop
and restart when the water temperature is below 18°C.
When the SET button is pressed for the third time, the display panel will
display
F3 - the defrosting time. The recommended setting is 5
minutes. To adjust setting YOU MUST PRESS THE ON/OFF BUTTON
FIRST. Use the UP and DOWN buttons to adjust defrosting time
between 3 to 15 minutes. Press on/off button again to take you back to
the normal display.
When the SET button is pressed twice, the display panel will display
F2- the defrosting cycle. The recommended setting is 30 minutes. To
adjust setting YOU MUST PRESS THE ON/OFF BUTTON FIRST.
Then use the UP and DOWN buttons to adjust defrosting period
between 30 minutes up to 99 minutes. Press on/off button again to take
you back to the normal display. The unit will now start to defrost after
the setting period when the defrosting sensor reaches the frosting
condition.
CONTROL PANEL FUNCTIONS 1-3
NOTE. WHEN PROCESSING FUNCTIONS F1-F5 IF NO ADJUSTMENTS ARE MADE FOR 5 SECONDS
THE DISPLAY WILL REVERT BACK TO THE CURRENT & DESIRED WATER TEMPERATURE AS ABOVE