Sierra 5300 Stove User Manual


 
9
A freestanding installation must be installed with 6" x 24
gauge (minimum) stove pipe from the stove flue collar to
the thimble of your chimney. The crimped end of each pipe
should be toward te stove. On horizontal pipe it should be
at least 1" higher where it enters the chimney than on the
end toward the stove. Do not use more than (2) elbows
and keep the length of the pipe to a minimum, but maintain
the clearances to combustibles.
See Figure 4, 5, & 6.
The Cricket may also be installed with a UL listed
manufactured chimney. These normally attach to the flue
collar of the stove ad extend straight up through the ceiling
and the roof. Make sure all the manufacturers
specifications are followed closely, especially when
passing through any combustible walls, ceilings, or roof.
Normally, an installation using manufacturer’s chimney is
beyond the expertise of the do-it-yourselfer.
Jacket Installation:
An optional jacket is available for your Cricket which
reduces clearances to combustibles to 8" from the sides
and rear of the unit.
If you purchased this accessory, it attaches to the stove
with the following steps: (See Figure 7)
1. Slide jacket over stove.
2. Bolt jacket on with one screw on either side of unit.
3. Hook top of jacket over lip at front of stove and lay
lid back over top of stove.