Shinco KFR-25GWZ Air Conditioner User Manual


 
Shinco Service Manual
- 29 -
119 0.2838 0.3129 0.3448 -9.30% 10.19%
120 0.2767 0.3052 0.3365 -9.34% 10.26%
7.2.4 outdoor discharge pipe R(0)=187.25K±6.3% ;B(0/100)=3979K±1% R-T datasheet
Temp.() R(min) (KΩ) R(cent) (KΩ) R(max) (KΩ)
ΔR(min) ΔR(max)
-20 488.35 526.61 565.60 -7.3% 7.4%
-19 461.94 497.84 534.41 -7.2% 7.3%
-18 437.15 470.87 505.17 -7.2% 7.3%
-17 413.89 445.57 477.76 -7.1% 7.2%
-16 392.05 421.83 462.06 -7.1% 9.5%
-15 371.54 399.54 427.94 -7.0% 7.1%
-14 352.27 378.61 405.31 -7.0% 7.1%
-13 334.16 358.96 384.06 -6.9% 7.0%
-12 317.13 340.48 364.10 -6.9% 6.9%
-11 301.11 323.11 345.34 -6.8% 6.9%
-10 286.03 306.77 327.71 -6.8% 6.8%
-9 271.83 291.40 311.13 -6.7% 6.8%
-8 258.46 276.92 295.52 -6.7% 6.7%
-7 245.86 263.29 280.83 -6.6% 6.7%
-6 233.98 250.44 266.99 -6.6% 6.6%
-5 222.78 238.33 253.96 -6.5% 6.6%
-4 212.20 226.91 241.67 -6.5% 6.5%
-3 202.22 216.13 230.07 -6.4% 6.4%
-2 192.79 205.95 219.13 -6.4% 6.4%
-1 183.88 196.34 208.80 -6.3% 6.3%
0 175.45 187.25 199.05 -6.3% 6.3%
1 167.33 178.66 190.00 -6.3% 6.3%
2 159.64 170.53 181.45 -6.4% 6.4%
3 152.37 162.84 173.34 -6.4% 6.4%
4 145.49 155.56 165.67 -6.5% 6.5%
5 138.97 148.66 158.39 -6.5% 6.5%
6 132.80 142.12 151.49 -6.6% 6.6%
7 126.95 135.92 144.94 -6.6% 6.6%
8 121.40 130.03 138.73 -6.6% 6.7%
9 116.13 124.45 132.83 -6.7% 6.7%
10 111.13 119.14 127.22 -6.7% 6.8%
11 106.38 114.10 121.89 -6.8% 6.8%
12 101.87 109.31 116.82 -6.8% 6.9%
13 97.585 104.75 112.00 -6.8% 6.9%
14 93.506 100.42 107.41 -6.9% 7.0%
15 89.625 96.289 103.04 -6.9% 7.0%
16 85.930 92.358 98.873 -7.0% 7.1%
17 82.411 88.612 94.902 -7.0% 7.1%
18 79.058 85.042 91.116 -7.0% 7.1%
19 75.861 81.637 87.503 -7.1% 7.2%
20 72.813 78.388 84.055 -7.1% 7.2%
21 69.904 75.287 80.768 -7.1% 7.3%
22 67.128 72.326 77.618 -7.2% 7.3%
23 64.477 69.498 74.612 -7.2% 7.4%
24 61.945 66.795 71.738 -7.3% 7.4%
25 59.525 64.210 68.990 -7.3% 7.4%
26 57.211 61.739 66.360 -7.3% 7.5%
27 54.998 59.373 63.843 -7.4% 7.5%