84 6.4273 7.0878 7.7850 -9.3% 9.8%
85 6.1825 6.8204 7.4942 -9.4% 9.9%
86 5.9462 6.5623 7.2135 -9.4% 9.9%
87 5.7184 6.3133 6.9424 -9.4% 10.0%
88 5.4987 6.0731 6.6808 -9.5% 10.0%
89 5.2867 5.8413 6.4284 -9.5% 10.1%
90 5.0827 5.6177 6.1847 -9.5% 10.1%
91 4.8853 5.4018 5.9495 -9.6% 10.1%
92 4.6953 5.1939 5.7226 -9.6% 10.2%
93 4.5121 4.9932 5.5037 -9.6% 10.2%
94 4.3355 4.7997 5.2925 -9.7% 10.3%
95 4.1653 4.6131 5.0840 -9.7% 10.2%
96 4.0012 4.4331 4.8922 -9.7% 10.4%
97 3.8431 4.2596 4.7026 -9.8% 10.4%
98 3.6908 4.0924 4.5198 -9.8% 10.4%
99 3.5440 3.9312 4.3435 -9.8% 10.5%
100 3.4025 3.7759 4.1735 -9.9% 10.5%
101 3.2663 3.6262 4.0097 -9.9% 10.6%
102 3.1351 3.4819 3.8517 -10.0% 10.6%
103 3.0087 3.3429 3.6995 -10.0% 10.7%
104 2.8870 3.2090 3.5528 -10.0% 10.7%
105 2.7699 3.0801 3.4114 -10.1% 10.8%
106 2.6571 2.9559 3.2720 -10.1% 10.7%
107 2.5485 2.8363 3.1440 -10.1% 10.8%
108 2.4441 2.7211 3.0176 -10.2% 10.9%
109 2.3435 2.6103 2.8959 -10.2% 10.9%
110 2.2468 2.5036 2.7787 -10.3% 11.0%
111 2.1537 2.4009 2.6658 -10.3% 11.0%
112 2.0642 2.3021 2.5572 -10.3% 11.1%
113 1.9781 2.2070 2.4526 -10.4% 11.1%
114 1.8954 2.1155 2.3519 -10.4% 11.2%
115 1.8158 2.0276 2.2551 -10.4% 11.2%
116 1.7393 1.9430 2.1619 -10.5% 11.3%
117 1.6657 1.8616 2.0723 -10.5% 11.3%
118 1.5951 1.7834 1.9861 -10.6% 11.4%
119 1.5272 1.7082 1.9032 -10.6% 11.4%
120 1.4619 1.6359 1.8234 -10.6% 11.5%
7.2 KFR-50GWZ/BMKFR-70GWZ/BM Sensor Resistance Table
7.2.1 indoor air sensor R(25)=5K±2% ;B(25/50)=3950K±2% R-T datasheet
Temp.() R(min) (KΩ) R(cent) (KΩ) R(max) (KΩ)
ΔR(min) ΔR(max)
-20 44.23 47.70 51.40 -7.3% 7.8%
-19 41.82 45.05 48.49 -7.2% 7.6%
-18 39.55 42.56 45.76 -7.1% 7.5%
-17 37.43 40.23 43.20 -7.0% 7.4%
-16 35.43 38.03 40.80 -6.9% 7.3%
-15 33.54 35.97 38.54 -6.8% 7.1%
-14 31.77 34.04 36.43 -6.7% 7.0%
-13 30.11 32.22 34.44 -6.5% 6.9%
-12 28.54 30.50 32.57 -6.4% 6.8%
-11 27.06 28.89 30.82 -6.3% 6.7%
-10 25.66 27.37 29.17 -6.2% 6.6%
-9 24.35 25.94 27.61 -6.1% 6.4%