HOW TO START AND OPERATE YOUR PELLET APPLIANCE
1. Check and fill hopper with
pellets.
2. Switch on power by pushing the
start up switch once only.
CONVECTION
BLOWER SPEED
CONTROL
3. Turn the Dial A Fire knob to the
12 o’clock position. (Lower
grade pellets may need a
higher setting on the feed
rate). NOTE: unit will take longer
to light if the hopper has been
completely emptied.
4. Wait until the fire is established,
then turn knob “B” to the desired
heat output. (The stove may not
be able to burn in the BLUE
ZONE if poor quality wood pellets
are being used.) Adjust the Slider
Damper to the appropriate
setting.
AUGER LIGHT
START-UP
SWITCH
5. If the stove should shut off after
15 minutes and there is still a fire
in the firebox – press the start up
switch once more. If the fire
went out, return to step number 2
and re-light the stove.
DIAL-A-FIRE
HEAT
OUTPUT
KNOB
6 Adjusting the blower speed
control knob will vary the rate of
airflow into the room by varying
the speed of the convection
blower. *Note: The convection
blower may cycle to high automatically depending on the setting of the controls. This is a normal
safety feature of the unit.
TURNING YOUR PELLET STOVE OFF
To turn your stove off, simply turn the HEAT OUTPUT knob (knob “B”) counter-clockwise until the knob
clicks to the “off” position. This will stop the feed of pellets. The blowers will continue to run and cool
the stove. When cool enough the stove will shut down.
SPECIAL NOTES:
- The flashing green light corresponds to the auger feed rate.
The scale on the Dial A Fire knob represents a range, not exact at times. Wood pellets of differing
quality may effect the performance of the stove. If the stove has trouble operating at the end of its
range, turn the heat output knob back slightly.
6