Sherwood EF-3 BAYI Stove User Manual


 
MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI
The Fireplace Insert model includes surround face plates and a pedestal. When installing this unit,
ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround
assembly instructions are in this manual).
CLEARANCE TO COMBUSTIBLES:
Side wall............................................8” (200 mm) from the body of the heater
Facing on masonry fireplace.............8” (200 mm) from the body of the heater
Mantle ...............................................8” (200 mm) from the body of the heater
FIREPLACE INSERT SIZE:
Width.................................................22” (550 mm)
Height................................................22 ¾” (570 mm)
Depth ................................................24” (600 mm)
A noncombustible hearth pad must cover combustible
flooring underneath, as well as 6” (150 mm) in front of the
heater and 6” (150 mm) to the side of the heater
1. Install the hearth pad
2. Lock fireplace damper in the open position
3. Install positive flue connector at the fireplace dampers.
4. Connect a tee or 90-° degree elbow to the exhaust pipe
5. This fireplace insert must be installed with a continuous
chimney liner of 3 or 4” diameter extending from the
fireplace insert to the top of the chimney. The liner must
conform to type 3 requirements of CAN/ULC S635.
6. (Recommended) Install fresh air intake either through the
back of the fireplace or through the positive flue connector..
When installing the insert into a masonry fireplace DO NOT
remove any bricks or masonry, with the following exception;
Masonry or steel, including the damper plate, may be
removed from the smoke shelf and adjacent damper frame if
necessary to accommodate a chimney liner. Provided that
their removal will not weaken the structure of the fireplace
and chimney, and will not reduce protection for combustible
materials to less than that required by the national building
code.
When installing the fireplace insert into a zero clearance
fireplace, DO NOT cut or modify any factory firebox parts. If
the fireplace insert does not fit into a zero clearance fireplace
we recommend you use an ENVIROFIRE model FS and
install as a hearth mounted unit. Install a 3” (76 mm) flex pipe from the stove to the top of the chimney.
14