Changing & Cleaning the Exhaust
Filter
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, dust cup filter,changing the filters or
performing maintenance/trouble shooting
checks.
The exhaust filter is located on the
front of the unit below where the dust
cup is.
1. Check the exhaust filter frequently
and clean when dirty.
2. Press inward on each side of the
exhaust filter cover and pull out to
remove from the vacuum cleaner.
3. Remove the exhaust filter.
4. Rinse in lukewarm water and dry
the filter completely before re-
installing into the vacuum. Do not
use a washing machine to rinse the
filter. Do not use a hair dryer to dry
it. Air dry only. Never operate the
vacuum without the filters in place.
5. When the filter is dry, replace into
the vacuum and replace the filter
cover.
Note:
A severely soiled or clogged
filter should be thoroughly washed with
fresh tepid water. A mild detergent can
be used if required.
Cleaning the Dust Cup
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, dust cup filter,changing the filters or
performing maintenance/trouble shooting
checks.
The dust cup can be washed in
lukewarm water. Do not use strong
detergents. Ensure that the dust cup is
fully dry before putting back on the
vacuum cleaner. (Fig. 16) Do not wash
in dishwasher.
Fig. 16
Motor Thermostat
Important: This motor is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
Push the On/Off button once.
Disconnect the plug from the
power source.
Check the source of overheating
problem. (i.e. clogged hose or
filter)
if clogged hose or filter is found,
unclog the hose and replace the
filters.
Wait at least 30 minutes before
attempting to reuse the vacuum.
After unit has cooled down for
30 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
If the vacuum still does not start,
contact EURO-PRO at 1-800-
798-7398.
8
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS
Changing & Cleaning the Pre-
Motor Filter
Occasionally the power nozzle drive
belt will require changing, the
frequency will depend upon the amount
of use your vacuum sees.
1. Turn the vacuum "Off" and unplug
from power supply.
2. Release the handle by pressing on
the handle release pedal and pull
back on the handle until it releases
from its upright position. Then turn
the vacuum over and place on the
floor.
3. With a Phillips #2 screw driver
remove the five screws on the
bottom plate. (Fig. 17)
Fig. 17
4. Carefully remove any residue that
may exist in the belt area.
5. If the belt has broken, remove any
loose pieces before replacing.
6. Hold the agitator with your hand. If
the belt is still attached to the
agitator, there will be tension on it.
7. Carefully lift the left side of the
agitator and then the right side.
8. Remove the worn or broken belt
from the motor drive shaft.
9. Loop the new belt first over the
drive shaft and then over the belt
pulley on the agitator. (Fig. 18)
10.Insert the right side of the agitator in
first by placing the rounded portion
of the end cap down into the slot
and then do the same with the left
side. Press firmly to make sure that
each end is completely inserted.
11.Check to make sure that the belt is
centered on the belt pulley and that
the agitator turns freely.
12.Replace the bottom plate over the
power head base and screw firmly.
Fig. 18
Changing the Headlight Bulbs
Warning: Always disconnect from
power source when servicing or
cleaning the unit. Failure to do so could
result in electrical shock or personal
injury from cleaner suddenly starting.
Turn unit “Off” and unplug from
wall outlet.
Snap the lens cover off by pressing
down to release the two notches on
the lens. (Fig. 19)
Remove the light bulbs by pulling
them out carefully.
Replace with new bulbs by pushing
them in.
Replace the lens cover.
Lens
Fig. 19
Cleaning & Changing the Belt
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, dust cup filter,changing the filters or
performing maintenance/trouble shooting
checks.
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, dust cup filter,changing the filters or
performing maintenance/trouble shooting
checks.
The pre-motor filter is located
underneath the dust cup. Please note
that this filter is not a washable filter
but should be cleaned frequently. To
remove the pre-motor filter:
1. Remove the dust cup from the
vacuum cleaner.
2. Make sure that you empty the dust
cup before turning it upside down to
remove the pre-motor filter.
3. Press inward on the two clips on
the side of the filter and pull out to
remove.
4. Clean the pre-motor filter by gently
tapping over a trash container.
5. Replace the filter into the dust cup
and push down until you hear it
click into place.