SECO-LARM USA SD-C141S Garage Door Opener User Manual


 
3
1 /
8
"
(34mm)
3
1 /
4
"
(44mm)
5
4 /
8
"
(117mm)
7
2 /8"
(73mm)
Digital Access Keypads
SK-1011-SQ One Output, 100 Users
SK-1131-SQ Three Outputs, 120 Users, Backlit Keypad
Door unlocked announcer
Request to exit input
Main relay lockout
Tamper switch
Silent operation
Operating voltage
Number of outputs
Number of users
Backlit keypad
Mantrap
Door forced open warning
Door propped open warning
Key activation output
Door auto relock
Alarm output
Duress output
LED connections
Yes
Yes
Yes
Yes
Yes
12~24 VAC/VDC
1
100
No
No
No
No
No
No
No
No
Fixed internal
SK-1011-SQ
Yes
Yes
Yes
Yes
Yes
12~24 VAC/VDC
3
120
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
External connection*
* LEDs can be wired to show status of external devices such as an alarm control panel.
SK-1131-SQ
SK-1011-SQ
SK-1131-SQ
Three outputs: Two relays, one transistor.
Backlit keypad: For easy daytime and nighttime use.
Mantrap: Ensures only one door can be opened at a time.
Duress output after multiple failed code entries.
Door-forced-open warning: Keypad beeps continuously
if the door to the protected premises is forced open.
Door-propped-open warning: Beeps continuously if the
door is open after the programmed open time elapses.
Alarm output: Can trigger an optional alarm control panel
if a protected door is forced open or propped open.
Keypad active output: Activates for 10 seconds when
any key on the keypad is pressed.
Door auto relock: Can relock an open door when
the relock time expires or after the door is closed.
Additional Features for SK-1131-SQ:
Ideal for access and security applications.
Code lockout after multiple failed code entries.
Stainless-steel face, durable and attractive.
Built-in buzzer for audible confirmation.
Form C relay output (5A@28VDC).
Output relay activation buzzer.
Relay output inhibit control (programmable) –
Locks the relay output to prevent user access.
Auto or manual code-entry checking.
Egress input -- Lets users exit the protected premises
without keying in the code.
Built-in tamper (N.C.) circuit.
EEPROM memory -- Prevents data loss.
Power -- 12~24 VAC/VDC, no need to change jumpers.
Shared Features:
Dimensions:
Model Comparison Chart:
Operating voltage
10mA@12VDC
30mA@12VDC
80mA@12VDC
5A@28VDC
N/A
10mA@12VDC
30mA@12VDC
130mA@12VDC (2 relays active)
5A@30VDC
6 oz (180g)
7 oz (200g)
1A@28VDC
100mA@24VDC
Standby
Key pressed
Relay output
Relay #1
Relay #2
Current draw
Relay output
N.O. ground
N.C. ground
Transistor ground output
Egress
Door sensor input
Weight
N/A
12~24 VDC/VAC
SK-1011-SQ SK-1131-SQ
Specifications:
Access