Sears 758.144533 Humidifier User Manual


 
Troubleshooting
Trouble Remedy
Unit will not run. Raise humidistat setting
Check 120 volt power source
Free float from obstructionUnit will not shut off.
Unit will not dry out
completely
I Bottles continue to
empty.
Unit is not emptying.
Unit runs and shuts
off before bottles are
empty
Probable Cause
Humidity level is too high
No power
Float is not free
Water is present in the
system
High humidity or low
temperature resulting in
slow evaporation
Air is entering water reser-
voirs.
Dirty filter
Reservoir cap plunger
missing post in bottom of
cabinet.
! Humidity level is too high
Unit is not setup on a level
surface (Float will not
sense water at the rear of
the cabinet.
This is normal. A small
amount of water remains in
the cabinet.
Allow unit to continue opera-
tion.
Check "E-Z-Fill Side-Caps" to
ensure tightness.
Check for leak in water bottles.
Are gaskets for "E-Z-Fill Side-
Caps" in place (see repair
parts list).
Change to a fresh new filter.
Check orientation of bottle.
Reposition so that reservoir
cap plunger is depressed by
post in bottom of cabinet.
Raise humidistat setting (if
possible)
Position unit level (Some car-
pet padding may allow unit to
set lower in the front than the
rear with the additional weight
of water bottles in the front of
the cabinet. Install coasters
under front casters.
CAUTION: Use only 42-14900 EPA Registered Bactedostat available from
Sears Retail store.
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use water treatment products designed
for Roto belt or Ultrasonic humidifiers.
13