Troubleshooting --.,.,.,,..,., "
Trouble Probable Cause
Unit wilt not run. oHumidity level is too high
- No power
* Float is not freeUnit wil_ not shut off.
Unit will not dry out
completely
Bottle continues to
empty.
Unit is not emptying.
Unit runs and shuts
off before bottle is
empty
• Water is present in the
system
• High humidity or low
temperature resulting in
i
stow evaporation
Air is entering water reser-
voirs.
Dirty filter
Reservoir cap plunger
missing post in bottom of
cabinet.
* Humidity level is too high
. Unit is not setup on a level
surface (Float will not
sense water at the rear of
the cabinet.
Remedy
Raise humidistat setting
• Check 120 volt power source
• Free float from obstruction
, This is normal. A small
amount of water remains in
the cabinet.
• Allow unit to continue opera-
tion.
• Check "E-Z-Fill Side-Caps" to
• ensure tightness.
Check for leak in water bottle.
• Are gaskets for "E-Z-Fill Side-
Caps" in place (see repair
parts fist).
• Change to a fresh new fi}ter.
• Check orientation of bottle.
Reposition so that reservoir
cap plunger is depressed by
post in bottom of cabinet.
, Raise humidistat setting (if
possible)
• Position unit level (Some car-
pet padding may allow unit to
set lower on the left side than
the right side due to the weight
of the water bottle on left side.
Install coasters under left cast-
ers.)
CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from
Sears Retail store,
Use of other water treatment products may damage the filter elements.
Under no circumstances should you use water treatment products designed
for Roto belt or Ultrasonic humidifiers.
t3