Sears 661.62453 Air Conditioner User Manual


 
CARE OF YOUR COOLER
CAUTION: ALWAYS UNPLUG YOUR COOLER BEFORE YOU WORK
ON IT YOU COULD BE HURT IFTHE COOLER IS TURNED
ON WHEN YOUR HANDS ARE tNS_DE THE COOLER
SPRING CARE:
Clean your cooler (See page 12)
Oil your cooler (See page 13)
Put a new pad in if the old pad is plugged with dirt or water hardness, (See pages 12 and 13).
Check belt tightness (See page 13)
SUMMER CARE:
FALL CARE:
Drain and clean the cooler every two months if your water is hard or the air is dusty
You may prolong pad life in many hard water areas if you drain the water tray every two to
three weeks (See page 12, Preventing mineral build-up),
Drain the cooler and water line to prevent freezing damage (See page I2)
Clean the cooler, (See page 12),
Cover the cooler
Sears has covers to fit your cooler
TAKING OFF LOUVER (FIGURE 17)
1 Unsnap the six louver clips
Use a small screwdriver
2 Tilt out the louver at the top
Unplug the pad motor plug
3 Take off the louver
Set it where it will not fall
PUTTING ON LOUVER (Figure 18)
1 Put the louver bottom into water tray
2 Plug in the pad motor
3 Close the louver
Snap the six clips onto the louver
INSERT SMALL SCREWDRWER
)ER CLIP, PRY OPEN
PAD MOTOR PLUG
tl