4A. DIMENSIONS/SPECIFICATIONS
BYPASS VALVES
SINGLE-PLASTIC
OUTWARD
FOR
Bypass
SINGLE-BRASS
Push
q;..
For SH
Bypass I INWARD
I FOR
ISERVICE
3-VALVE
SE_RVICE
Close Bypass Valve
Open Inlet & Outlet Valves
BYPASS
Open Bypass Valve
Close Inlet & Outlet Valves
Outlet
Valve
Bypass
Valve
i Inlet
Valve
A
_F_
l ....
x" \
/ \
I
I
I
I
I
\ /
D
C
E
INCHES CM
A Salt Tank Height 40-1/4 102.2
B Resin Tank Diameter (nominal) 8 20.3
C Resin Tank Height (nominal) 40 101.6
D Inlet-Outlet Height 41-1/2 105.4
E Overall Height 46 116.8
F1 Length 19-1/2 49.5
F2 Width 16-1/2 41.9
-- Distance between inlet-outlet 3-3/8 8.6
center lines
MODEL NO. 625.348420 TIMER SR CODE SR17
NOTE:
Ple_tse see the r_tting (tec_fl for w_tter softener oper_tting cap_tcity, s_flt us_tge _tn(t servk:e flow r_tte/pressure loss
perform_mce specific_ttions. Performance specific_ttions are v_flidated by the W_tter Qu_flity Associ_ttion (WQA).
The r_tting dec_fl is loc_tted on the rim, under the s_flt hole cover (see p_tge 28).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATER SYSTEM FLOW (gpm) 3
MINIMUM-MAXIMUM WATER PRESSURE (psi) ..... 20-120
MAXIMUM WATER TEMPERATURE (°F) 120
MAXIMUM WATER HARDNESS (gpg) 90*
MAXMUM "CLEAR WATER" IRON (ppm) 3
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED Nugget/Pellet
ALTERNATE TYPE OF SALT -- Pure, evaporated, compacted
water softener salt
STORAGE CAPACITY (pounds) 200
*Do not exceed this number when setting hardness in step 2,
page 7. The maximum setting available is 95.
OTHERS
TYPE OF ION EXCHANGE MATERIAL (resin)
AMOUNT OF RESIN (cu.ft.)-
REGENERATION (RECHARGE) CYCLE TIME (min.)
FILL 2-8
BRINING/BRINE RINSE 103
BACKWASH 7
FAST RINSE 3
TOTAL REGENERATION TI ME 115-121
High Capacity
.6
gpm = gallons per minute
gpg = grains per gallon
psi = pounds per square inch
ppm = parts per million