Sears 625.34842 Water System User Manual


 
SECTION 5 SERVICE TECH. INFORMATION
I I
5A. TROU BLES HOOTI NG
Keep this manual with your water softener. If repairs are needed, the SelWice technician must have the
informadon on the following pages. For telephone assistance, call toll free, 1-800-426-9345.
110
VAC
TRANSFORMER
24VAC
I IRCUIT BOARD
li'
()
ii
I=
__ Shield
BINE
ENSOR
WIRING SCHEMATIC
NO
Wh .0-"_ POSITION SWITCH
0
grn NO
f
UP button
display "7
ON/OFF-HOLD button "
(Recharge Tonight-Now)
Sears WaterLine
for CustomerAssistance
1-800-426-9345 _ _._ ...............
J
SELECT button
DOWN
button
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. Does the time display show the correct time of day?
2.
- If display is blank, check power source to the
softener.
- If time is flashing, power was off for over 6 hours.
The softener resumes normal operation but regen-
erations occur at the wrong time.
- If an error code (Example: Err 03) shows in the face
plate display, go to Azdomatic iZ/ectromic Dia/qmos-
tics.
Plumbing bypass valve(s) must be in Full Service
position.
3. The inlet and outlet pipes must connect to the
softener valve inlet and outlet respectively.
4. Is the transformer plugged into a "live", grounded
wall outlet, and is the power cable fastened securely?
5. The valve drain hose must be flee of kinks and sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
6. Is there salt in the storage tank?
7. Is the brine tubing connected? (See water flow
diagrams).
8. Is the brine valve float set right? (See page 22).
9. Press the SELECT button 2 times to display the
hardness setting. Be sure it is the correct setting for
the household's water supply. (Make a hardness test
of the raw water and compare with the hardness
setting. Also test a soft water sample to verify if a
problem exists.) Press SELECT twice more to return
the time of day display.
If you do not find the problem after making initial checks,
do the Mamlal Initiated Electronic Diagnostics, and the
Manual Advance Regeneration Check.
19