Sears 390.303302 Water Pump User Manual


 
4. This pump is recommended for use in permanent instal-
lations only. Do not install on clay, earth, or sand surfaces.
A j Pump must be level (column must be verti-
1
CAUTION
cal) when operating. If motor is tilted, internal start/run
switch may overheat and damage motor.
ADDITIONAL INSTALLATION
MATERIALS
SumpFLTtility Pump Hose Kit, SEARS Stock No. 27909, con-
taining 24' of 1-1/4" flexible plastic pipe, a 1-1/4" plastic
adapter and a stainless steel clamp.
Check Valve, SEARS Stock No. 2789 or 2792.
THE SUMP
The sump should be located at the lowest place in the base-
ment or area to be drained. Floor drains from other areas in
the basement may be tiled into the sump. Drain tile around
a house foundation can also be tried into the sump, effec-
tively removing water and relieving pressure from this area.
A suitable sump can be a 20" or 24" sewer tile. Sump must
be at least 12" in diameter.
A sump cover is desirable to exclude refuse from the sump.
Consult local code for sump cover specifications.
SPECIFICATIONS
Power supply required .................................... 115V, 60 HZ.
Horsepower (390.303302) ............................................. 1/3
Horsepower (390.303491) ............................................. 1/2
Motor duty ......................................................... Intermittent
Liquid Temp. Range ........................ 32 ° F to 70 ° F (0°-21°C)
Individual Branch Circuit
Requirement GFCI Class A...................................... 15 Amps
Motor full load (maximum - 390.303302) ............. 3.5 Amps
Motor full load (maximum - 390.303491) ............. 7.3 Amps
Discharge (390.303302) ...................................... 1-1/4" NPT
"_ischarge (390.303491) ...................................... 1-1/2" NPT
PUMP INSTALLATION
Check your local Electrical and Plumbing Codes before in-
stalling pump. You must comply with their rules.
Set the pump on the bottom of the sump, making sure that
it sits solidly and is level. Be sure there is enough space
around the pump to allow the switch free movement as
the sump water level changes. Do not install on clay,
earth, or sand.
[A _ Risk of flooding. If a flexible discharge
hose is used, pump may move around in sump
when motor starts. If it moves far enough so that the
switch hits the side of the sump, the switch may stick and
prevent pump from starting. Make sure that pump is se-
cured so that it cannot "walk around" in sump.
NOTE: To avoid backflow into the sump when the pump
shuts off, install a Check Valve, SEARSStock No. 2789, in the
threaded discharge port of pump (390.303302) or 1-1/2"xl-
1/4" reducer bushing (390.303491). Reducer bushing is in-
cluded with Model 390.303491. Be sure arrow on check
valve body points away from the pump. This Check Valve is
equipped with an air bleed hole to prevent airlocking the
pump. If using any other check valve, drill 1/8" (3.2 ram)
hole in discharge pipe just above pump body but below
check valve to prevent air locks.
Use 1-1/4" plastic pipe from Hose Kit No. 27909 for the dis-
charge pipe. Run the discharge pipe to the nearest sewer
outlet or other point of disposal. Use the most direct route
with the fewest turns and elbows possible.
Use Teflon tape to seal threads in plastic pipe. Hand tighten
only.
20=to 24"
SewerTile , ',',,
Sump Cover
1/4" \ BasementFloor
SewerTile
12"Mm _ Concrete
+ g
20"to24"Diam.
Figure I