INSTALLATION STEP 7
Install the Lights and Lenses
• Install a 75 watt maximum light bulb in each
socket. The lights will turn ON and remain lit for
approximately 4-1/2 minutes when power is
connected. Then the lights will turn OFF.
• Apply slight pressure on the sides of each lens
and slide the tabs into the slots in the side panels.
(See illustration.)
• For convenience, the lenses may be installed
after Adjustment Step 4 on page 30.
• To remove, reverse the procedure. Use care to
avoid snapping off lens tabs.
• Use standard neck Garage Door Opener bulbs for
replacement.
/
Lens
Tab
75 Watl Max.
LenSrab/_ Lighl Bulb
Lensf
Tab
Lens
Guide
Lens
Siot
/
INSTALLATION STEP 8
Attach the Emergency Release
Rope and Handle
• Thread one end of the rope through the hole in the
top of the red handle so "NOTICE" reads right side
up as shown. Secure with an overhand knot at
least 1" from the end of the rope to prevent
slipping.
• Thread the other end of the rope through the hole
in the release arm of the outer trolley.
• Adjust rope length so the handle is 6 feet above
the floor. Secure with an overhand knot.
NOTE: If it is necessary to cut the rope, heat seal
the cut end with a match or lighter to prevent
unraveling.
• Toprevent possible SERIOUSINJURYor DEATHfrom
a falling garagedoor:
- If possible, use emergency releasehandleto
disengage trolley ONLYwhen garagedoor is
OLOSED.Weakor broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
- NEVERuse emergency releasehandle unless garage
doorway is clear of persons and obstructions.
• NEVERusehandle to pull door open or closed. If rope
knot becomes untied, you could fall.
Trolley
Emergency _, _) KCVe[hand
Release Handle i_
19