Sanyo XHS3632 Air Conditioner User Manual


 
1
2
3
4
– 9 –
SM830076
1. Specifications
1-1 Unit Specifications
MODEL No. Indoor Unit XHS3632
Outdoor Unit CH3632
POWER SOURCE 230 - 208 VAC / 1 Phase / 60 Hz
PERFORMANCE Cooling Heating
Capacity* BTU / h 34,500 33,500 37,500 36,500
(17°F)** 25,000 23,500
Moisture removal (High) Pints / h 11.1 11.1
Air circulation (Hi)
cu.ft. / min.
980 / 880
S.E.E.R. (H.S.P.F.)
BTU / Wh
10.7 11.0 (7.0) (7.0)
ELECTRICAL RATINGS
Voltage rating VAC 230 208 230 208
Available voltage range VAC 187 - 253 187 - 253
Running amperes A 15.4 15.8 18.2 19.3
Max. running amperes A
Power input* W 3,350 3,200 3,850 3,750
(17°F)** 3,150 2,950
Buck-up heater kW
Maximum fuse size A 30
FEATURES
Controls Microprocessor
Fan speeds Indoor / Outdoor 3 and Automatic control / 2 (Auto)
Timer ON / OFF 24-hours & Program
Air deflection Horizontal / Vertical — / Automatic
Air filter Washable, easy access, long life fiter (2,500 hr)
Operation sound Indoor dB - A 43 / 40 / 36
Hi / Me / Lo Outdoor - Hi dB - A 56
Refrigerant control Electronic Refrigerant Control Valve
REFRIGERANT PIPING
Limit of piping length ft. (m) 165 (50)
Limit of piping length at shipment ft. (m) 100 (30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit: 165 (50)
between the two units Outdoor unit is lower than indoor unit: 100 (30)
Refrigerant piping Narrow pipe in. (mm) 3 / 8 (9.52)
Flare type Wide pipe in. (mm) 3 / 4 (19.05)