Sanyo XHS2432 Air Conditioner User Manual


 
1
2
3
4
– 11 –
SM830076
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No. XHS2432
Source 230 - 208 VAC / 1 phase / 60 Hz
Remote controller (Accessory) RCS - 5HPS4U
Controller P. C. B Ass'y CR - THS2432
Control circuit fuse 250 VAC, 3 A
Controller Ass'y CR - 3XHS
Fan (Number … diameter) in. (mm) Turbo (1…19-9/32 (490))
Fan motor
Model SFG6X - 41A5P
Source 230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High) rpm 6 … 451
Nominal output W 40
Coil resistance BRW - WHT : 114.0 , ORG - YEL : 66.4
(Ambient temperature 68 °F) WHT - VLT : 23.9 , WHT - PNK : 77.4
VLT - ORG : 12.4 , YEL - BLK : 82.1
Safety device
Operating temperature Open °F266± 14.4
Close °F 174.2 ± 27
Run capacitor VAC, µF 440 V , 4 µF
Electronic expansion valve
Coil DKV - MOZS582E0
Coil resistance (at 20°C) ORG - GRY : 46 , YEL - GRY : 46
RED - GRY : 46 , BLK - GRY : 46
Valve body IKV - 24D12
Heat exchanger
Coil Aluminum plate fin / Copper tube
Rows … Fins per inch 2 … 14.9
Face area ft.
2
(m
2
) 3.18 (0.295)
Panel
Model No. PNR - XHS2432
Indicator Lamp Ass'y IND - 3THS
Auto louver motor MT8 - 3C
Auto louver motor … Rated V, W, rpm 240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77 °F) 16.430 ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE