Sanyo XH2672R / C2672R Air Conditioner User Manual


 
1
2
3
4
5
6
I-4
SM831148
1. Specifications
1-1 Unit Specifications
Wall-Mounted Type
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
Indoor Unit KH3072R
Outdoor Unit CH3072R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling Heating
Capacity * [minimum~muximum] BTU / h 29,800 [9,500~29,800] 34,800 [8,000~34,800]
(17˚F)** BTU / h 20,000
Moisture removal (High) Pints / h 9.7
Air circulation (H / M / L) 230 V CFM 840 / 740 / 620
External Static Pressure
in. WG
S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 15.0 9.0
ELECTRICAL RATINGS
Voltage rating V 230 208 230 208
Available voltage range V VAC 187 - 253 VAC 187 - 253
Max. Running amperes* A 17.7 19.6 16.2 17.9
Power input W 3,690 3,690 3,390 3,390
(17˚F)** W 2,460 2,460
Back-up Heater kW
Maximum overcurrent protection (Indoor/Outdoor)
A 15 / 35
Low ambient control Built-in 0˚F
Fan speeds Indoor / Outdoor 3 and Automatic control / Variable
Optional Wired Remote Controller
Optional Wireless Remote Controller RCS-SH1UA / RCS-BH80UA. WL
Air deflection (Horizontal / Vertical )
/ Automatic (Vertical )
Air filter Washable
Drain pump (Drain connection) (20A , OD26mm)
Compressor Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A 46 / 42 / 38
Outdoor - Hi dB - A 52
Refrigerant control Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length ft. (m) 165 (50)
Limit of tubing length at shipment ft. (m) 10~100 (3~30)
Limit of elevation difference ft. (m) Outdoor unit is higher than indoor unit : 100 (30)
between the two units ft. (m) Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube Narrow tube in. (mm) 3 / 8 (6.35)
outer diameter Wide tube in. (mm) 5 / 8 (15.88)
Refrigerant amount at shipment lbs. (kg) 5.73 (2.6) - R410A
DIMENSIONS & WEIGHT
Indoor unit Outdoor unit
Unit dimensions Height in. (mm) 14- 9/16 (370) 30- 23/32 (780)
Width in. (mm) 59- 1/16 (1,500) 37 (940)
Depth in. (mm) 9- 7/16 (240) 13- 3/8 (340)
Package dimensions Indoor unit Outdoor unit
Height in. (mm) 18- 7/16 (468) 34- 31/32 (888)
Width in. (mm) 62- 9/16 (1,589) 39- 31/32 (1,015)
Depth in. (mm) 12- 9/16 (319) 16- 3/32 (409)
Net weight lbs. (kg) 63.9 (29) 143 (65)
Shipping weight lbs. (kg) 81.6 (37) 161 (73)
Shipping volume cu.ft. (m 3 ) 8.4 (0.237) 13.0 (0.369)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
Controls Microprocessor
RCS-SH80UG / RCS-TM80BG